Troubleshooting

For operations

Problem
The camera cannot be turned on.
The camera cannot be operated from the ROP
(AK-HRP1000G) that is connected via IP.
Chapter 6 Maintenance — Troubleshooting
Does the power cable plugged into the power outlet securely?
Is the power turned on?
• • If the power lamp of the camera is not lit, the power of the camera is off.
Is a valid IP address of the camera set?
Is the correct camera to be operated selected?
Is the camera connected with the ROP (AK-HRP1000G) correctly?
• • Also refer to the Operating Instructions of AK-HRP1000G.
The ROP (AK-HRP1000G) may require upgrading to support the camera.
• • Contact your dealer.