Information
Installation Area
Please refer to the various model drawings for the positioning of the
shower head and other components (inset box, transformer, etc.).
Please respect the distances with regards the ceiling and the false
ceiling.
The positioning of the mixer, side jets and the shower slider holder
(all available as Jacuzzi® optionals) must be requested from the in-
staller according to Customer requirements.
Hot/Cold Water
The hot and cold water pipes which supply the shower head must
have a suitable diameter; we recommend that pipes capable of ac-
commodating high flow rates are used when connecting the afore-
mentioned pipes and the shower head (internal Ø 10 mm).
In order to ensure correct operation of the appliance, the following
must be ensured: hot and cold water flow rates and pressure, in ad-
dition to the use of pipes as described in the previous paragraph.
Where "hard" water is present, it is advisable to install
a decalcifier in the water system supplying water to the
appliance, in order to reduce and/or avoid calcareous
deposits.
ATTENTION: (IEC 60335-1/A2) The pressure of the water
system supplying water to the appliance must not exceed
600 kPa (6 bar).
Electrical safety
The Jacuzzi® Caleidos shower heads are safe appliances manufac-
tured according to standard
61000, EN 55014-1, EN 55014-2
They are tested during manufacturing in order to guarantee user safety.
Installation must be carried out by qualified and authorized per-
sonnel, in compliance with the national provisions in force.
NOTE:
- the cables which connect the control panel to the shower head are
already connected to the aforementioned shower head.
- the cables which connect the control panel to the feeder and to the
aromatherapy module (optional) must be prepared during the installa-
tion phase, as should connection of the feeder to the building's electri-
cal system.
Only use the feeder provided; the use of other feeders may re-
sult in damage to the product and may result in the lapse of the
warranty.
EN 60335-1, EN 60335-2-105, EN
.
Feeder installation
must comply with legal standards and regula-
tions in the Country where the appliance is installed and the feeder
must be installed in an area that complies with the safety regula-
tions governing bathroom safety.
It is the installer's responsibility to select the materials, to
carry out the installation correctly; and to verify the con-
dition of the network to which the appliance will be con-
nected and its capability to ensure safety.
The building's electrical system and ground system must
be efficient and must conform to legal regulations and
specific national standards.
An appropriate device must be provided, which forms part
of the fixed system, and installed in compliance with cur-
rent legislation in force, with the purpose of disconnect-
ing the appliance from the mains.
For connection to the supply network, we advise installing an isolat-
ing multi-pole switch, which will ensure complete disconnection in
the instance of a category III over voltage; this device must be con-
nected to an area that complies with the safety regulations govern-
ing bathroom safety.
Switches and electrical devices, according to regulations,
must be connected to areas out of the user's reach.
If the building's electrical system is not able to guaran-
tee a stabile power supply, it is recommended to install
a voltage stabiliser that suitably dimensioned for the
required power upstream of the equipment.
The installation of electrical devices and appliances within bath-
rooms (sockets, switches, etc. which do not form part of the product,
with the exception of the aromatherapy module) must comply with
legal standards and regulations in the Country where the appliance is
installed; no electrical installation is to be carried out in the immedi-
ate area surrounding the appliance; a distance of at least 60 cm and a
height of at least 225 cm must be respected.
0,6 m
The appliance is equipped with a LED lighting system in compli-
ance with Norm EN 62471:2009.
The building's electrical supply must be equipped with a
differential switch with operating current which does not
exceed 0.03 A.
ATTENTION! Before carrying out any maintenance opera-
tion, disconnect the appliance from the power supply line.
7