Download Print this page

Manufacturer's Warranty; Technical Specifications; Troubleshooting - STEINEL L 220 LED Information

Advertisement

Available languages

Available languages

8. Manufacturer's warranty

This Steinel product has been manufactured with
utmost care, tested for proper operation and safety
and then subjected to random sample inspection.
Steinel guarantees that it is in perfect condition
and proper working order. The warranty period is
36 months and starts on the date of sale to the
G B
consumer. We will remedy defects caused by
material flaws or manufacturing faults. The warran-
1
ty will be met by repair or replacement of defective
Y E A R
parts at our own discretion. The warranty shall not
cover damage to wear parts, damage or defects
MANUFACTURER'S
caused by improper treatment or maintenance.
WARRANTY
Further consequential damage to other objects
shall be excluded.

9. Technical specifications

Dimensions (W × H × D)
L 240/L 244 LED 165 × 305 × 81
L 220/L 224 LED 246 × 251 × 84
Voltage supply
220-240 V, 50 / 60 Hz
Output
L 220 7.5 W 550 lm 73.3 lm/W
L 224 7.5 W 410 lm 54.7 lm/W
L 240 7.5 W 570 lm 76.0 lm/W
L 244 7.5 W 500 lm 66.7 lm/W
Colour temperature
3000 K (warm white), SDCM 3
Colour rendering index
Ra ≥ 80
LED life expectancy
50,000 h (L70B10 to LM80)
Sensor technology
Passive infrared
Angle of coverage
180°
Reach
max. 10 m
Time setting
8 s - 35 min
Twilight setting
2-2000 lux
IP rating
IP 44
Protection class
II
Impact resistance
IK 07
Temperature range
-20° to +50°C
Claims under the warranty will only be accepted
if the unit is sent fully assembled and well-packed
with a brief description of the fault, a receipt or
invoice (date of purchase and dealer's stamp) to
the appropriate Service Centre.
Repair service:
If defects occur outside the warranty period or are
not covered by the warranty, ask your nearest ser-
vice station for the possibility of repair.
5
3
Y E A R
Y E A R
MANUFACTURER'S
MANUFACTURER'S
WARRANTY
WARRANTY
– 12 –

10. Troubleshooting

Malfunction
Cause
Sensor-switched light
■ Fuse faulty, not switched ON,
without power
break in wiring
Sensor-switched light
■ Surroundings still too bright
will not switch ON
■ Mains switch OFF
■ Fuse blown
■ Detection zone not correctly
adjusted
Sensor-switched light
■ Continued movement within
will not switch OFF
the detection zone
Sensor-switched light
■ Cars in the street are detected,
switching ON when it
for example
should not
Changing reach
■ Differing ambient temperatures
Remedy
■ Fit new fuse, turn ON mains
switch, check wiring with voltage
tester
■ Wait until response threshold is
reached or adjust setting
■ Switch ON
■ Fit new fuse, check connection
if necessary
■ Readjust
■ Check detection zone and
readjust if necessary
■ Check detection zone and
readjust if necessary
■ When it is cold, shorten reach
by tilting sensor down,
move it up in warm weather
– 13 –