Pump-Machines With Wacker Engines; Sound Specifications-Machines With Wacker Engines - WACKER Group PG 2 Repair Manual

Table of Contents

Advertisement

PG Pumps
2.8
Pump—Machines with Wacker Engines
Item Number:
Dimensions
(L x W x H)
Operating Weight
*Max. Suction Lift
Max. Discharge Head
Suction / Discharge Dia.
Maximum Solid Size
Max. Flow Rate
* Based on pump operating at sea level. Maximum suction lift will be less at higher altitudes.
2.9
Sound Specifications—Machines with Wacker Engines
wc_td000183gb.fm
mm
(in.)
kg (lbs.)
m (ft.)
m (ft.)
mm (in.)
mm (in.)
l/m (gpm)
The required sound specification, Paragraph 1.7.4.f of 89/392/EEC
Machinery Directive, is:
the sound pressure level at operator's location (L
PG 2 = 84 dB(A), PG 3 = 87 dB(A).
the guaranteed sound power level (L
PG 2 = 103 dB(A), PG 3 = 105 dB(A).
These sound values were determined according to ISO 3744 for the
sound power level (L
(L
) at the operator's location.
pA
PG 2
0009496, 0009497
Pump
480 x 375 x 395
(19 x 15 x 15.5)
24 (53)
30 (98)
50 (2)
6.5 (0.25)
600 (158)
):
WA
) and ISO 6081 for the sound pressure level
WA
15
Technical Data
PG 3
0009498, 0009499
515 x 405 x 460
(20 x 16 x 18)
31 (69)
8 (26)
75 (3)
970 (256)
):
pA

Hide quick links: