- Action to avoid the hazard. Taking the product out of operation Short-term shutdown 1.2 Notes Long-term shutdown The symbols and notes below may appear in Grundfos Identification installation and operating instructions, safety instructions and Nameplate service instructions. Type key...
2. Service tools 2.1 Special tools Pos. Description For pos. Further information Part number Punch (brass) SV0282 Bearing heating inductor (for assembly) 53, 54 Round nut tool 2.2 Standard tools Pos. Description For pos. Further information Part number 1 - 1/2" 1 - 5/16"...
Death or serious personal injury If you request Grundfos to service the product, contact Grundfos - Pay attention to the direction of the vent hole, and with details about the liquid before returning the product for ensure that the escaping water does not cause service.
6. Loosen the set screws in the coupling flange of the pump. Black pearl NLGI 2 7. Pull the coupling flange off the pump shaft using a puller. Philips Polytac Texaco Polystar RB Grundfos recommends Shell Gadus S2 V2202 or SKF LGHP 2 grease for relubrication.
Page 7
Removing the bearings and shaft seals, non-drive end 4.2.2 LS with sleeve, construction type 2 1. Remove the four screws (114a) holding the bearing cover The position numbers in the following refer to section 9.2 LS with (113d). sleeve, construction type 2 on page 23. 2.
Page 8
Removing the shaft, impeller and gasket Removing the upper pump housing 1. Lift the shaft (51), including the impeller (49) and wear rings 1. Loosen the screws (26c, 26d), and remove them. (45b), free of the lower pump housing (6b). 2.
Removing the bearings and shaft seals, drive end 4.3 Dismantling the pump, without sleeve 1. Remove the key (11a). 4.3.1 LS without sleeve, construction type 1 2. Remove the four screws (114a) holding the bearing cover The position numbers in the following refer to section 9.5 LS (113c).
4.3.2 LS without sleeve, construction type 2 Removing the upper pump housing 1. Loosen the screws (26c, 26d), and remove them. The position numbers in the following refer to section 9.6 LS without sleeve, construction type 2 on page 25. 2.
Page 11
Fitting the upper pump housing 4.4.2 LS with sleeve, construction type 2 1. Clean the packing face of the upper pump housing (6a), and Fitting the impeller fit the pump housing. 1. Fit the shaft (51) in the impeller (49). 2.
Page 12
Fitting the bearings and shaft seals Fitting the upper pump housing 1. Clean the O-ring on the shaft seal rotary part (105). Then fit it 1. Clean the packing face of the upper pump housing (6a), and along with the washer and spring. Start at the non-drive end. fit the pump housing.
Page 13
4.4.4 LS with sleeve, construction type 4 Fitting the bearings and shaft seals 1. Clean the O-ring on the shaft seal rotary part (105). Then fit it Fitting the impeller along with the washer and spring. Start at the non-drive end. 1.
9. Install the bearing into the bearing (54) housing. Then install 4.5 Assembling the pump, without sleeve the washer and tighten the round nut. 4.5.1 LS without sleeve, construction type 1 10. Lock the nut by a lock washer. Fitting the impeller 11.
Fitting the bearings and shaft seals 4.6.2 Assembly 1. Clean the seal head surface using clean paper. Install the seal 1. Measure the length of the used packing ring, and cut off a new head on the shaft, rely onto the seal retainer ring (105b). Start one of the same length.
4. Checking angular alignment 5. Alignment Insert a pair of inside callipers or a taper gauge at four points at 5.1 Preliminary alignment 90 ° intervals around the coupling. See fig. 9. The angular alignment is correct when the measurements show that all points DANGER of the coupling faces are within 0.2 mm of each other.
The coupling alignment procedure has four steps: Angular alignment - vertically Parallel alignment - vertically 1. Turn the motor and pump shaft until the dial gauge (1) is in position 0 ° (12 o'clock). 1. Mount the dial gauge (2) in position 0 ° (12 o'clock). See fig. 2.
7. Identification CAUTION Hot or cold surface 7.1 Nameplate Minor or moderate personal injury - Make sure that the escaping water does not cause injury to persons or damage to the motor or other components. LS100-80-242E/235 1F2DS BBQE 1 11/4 - In hot-water installations, pay special attention to 99281199 P1 1832 0001 WRAS23C...
7.2 Type key Code Example -100 -305X /273.1 , (W) D S BBQE 1 Type range LS horizontal version Nominal diameter of the inlet port (DN) Nominal diameter of the outlet port (DN) Maximum impeller diameter [mm] If suffix is used: "X"...
Page 20
With internal barrier fluid Synthetic polymer packing rings, graphite Example impregnated. NBR O-ring in the pump Grundfos type designation Material, rotating seal face Material, stationary seat Material, secondary seal and other rubber and composite parts The following table explains the positions (1), (2), (3) and (4).
8. Standard components and material specifications Pos. Description Material Material standard Cast iron ASTM A48 Class35 Pump housing, upper Ductile iron ASTM A536, 65-45-12 Cast iron ASTM A48 Class35 Pump housing, lower Ductile iron ASTM A536, 65-45-12 Key, impeller Steel ASTM A216 WCB Key, coupling Steel...
10.2 LS with sleeve 10.2.1 Construction type 1 Fig. 14 Construction type 1: LS 65-50-241, LS 65-50-330, LS 100-80-241 X2...
Page 28
10.2.2 Construction type 2 Fig. 15 Construction type 2: LS 150-125-305, LS 150-125-381, LS 200-150-305C Fig. 16 Construction type 2: LS 125-100-279, LS 125-100-381, LS 125-100-305, LS 100-80-356, LS 200-150-305A...
Page 29
10.2.3 Construction type 3 Fig. 17 Construction type 3: LS 200-150-483 X5...
Page 30
Fig. 18 Construction type 3: LS 100-80-241 XE...
Page 31
Fig. 19 Construction type 3: LS 200-150-381, LS 250-200-305, LS 250-200-381, LS 300-250-305 Fig. 20 Construction type 3: LS 300-250-381...
Page 32
10.2.4 Construction type 4 Fig. 21 Construction type 4: LS 400-350-397 Fig. 22 Construction type 4: LS 350-250-498, LS 350-250-630...
Page 33
Fig. 23 Construction type 4: LS 200-150-508 Fig. 24 Construction type 4: LS 200-150-483 X6...
Page 34
Fig. 25 Construction type 4: LS 300-200-489, LS 350-250-508...
10.3.1 Construction type 1 105a 105b 113c 113g 109b 124d 124c 113f 113d 113e 114a Fig. 26 Construction type 1: LS 65-50-241, LS 65-50-330, LS 100-80-241 105a 105b 113c 113g 124d 124c 113f 113d 113e 114a Fig. 27 Construction type 1: LS 100-80-356...
Page 36
20d 20e 17 105a 113c 105b 113g 124d 124c 113f 114a 113e 113d Fig. 28 Construction type 1: LS 150-125-305, LS 150-125-381, LS 200-150-305 105a 105b 113c 113g 124d 124c 113f 113d 113e 114a Fig. 29 Construction type 1: LS 125-100-279, LS 125-100-305...
Page 37
105a 105b 113c 113g 113f 124c 124d 114a 113e 113d Fig. 30 Construction type 1: LS 125-100-381 113c 105a 113g 105b 124d 124c 113f 113e 113d 114a Fig. 31 Construction type 1: LS 200-150-483...
Page 38
105a 105b 124d 124c 113c 113g 113f 113d 113e 114a Fig. 32 Construction type 1: LS 200-150-381, LS 250-200-305, LS 250-200-381, LS 300-250-305 105a 105b 124d 124c 113c 113f 113g 113d 114a 113e Fig. 33 Construction type 1: LS 300-250-381...
Page 39
10.3.2 Construction type 2 113g 105a 105b 124d 124c 113c 109a 113f 113f 114b 113e 113d 114a Fig. 34 Construction type 2: LS 350-250-498 105a 105b 124c 113c 113g 124d 109a 114b 113f 113d 113e 114a Fig. 35 Construction type 2: LS 450-350-397...
Page 40
113g 105a 105b 124d 124c 113c 109a 113f 113f 114b 113e 113d 114a Fig. 36 Construction type 2: LS 350-250-630 105a 124c 105b 124d 113c 113g 113f 113f 114b 113e 113d 114a Fig. 37 Construction type 2: LS 200-150-508...
Page 41
113c 113g 105a 124c 105b 124d 113f 113f 114a 114b 113e 113d Fig. 38 Construction type 2: LS 200-150-483 X6 113c 105a 113g 105b 124d 124c 109a 114b 113f 113f 113d 113e 114a Fig. 39 Construction type 2: LS 300-200-489, LS 350-300-508...
11. Fault finding the product DANGER Electric shock Death or serious personal injury - Before you remove the terminal box cover and before you remove or dismantle the pump, make sure that the power supply has been switched off and that it cannot be accidentally switched on. Faults Causes The pump delivers no liquid.
Extend the inlet pipe so that the risk of sucking air is eliminated. enough. Check with Grundfos if you can use a larger impeller. If not, reduce the outlet pipe The impeller diameter is too small. friction losses. But be careful not to seriously overload the motor.
Page 47
Brazil Turkey Unit 1, Ground floor Norway BOMBAS GRUNDFOS DO BRASIL GRUNDFOS POMPA San. ve Tic. Ltd. Sti. Siu Wai Industrial Centre GRUNDFOS Pumper A/S Av. Humberto de Alencar Castelo Branco, Gebze Organize Sanayi Bölgesi 29-33 Wing Hong Street &...