  • Page 1 Lagom Stove User Guide Lagom PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE EN 13240:2011 +A2:2004 BK 746 SPECIFIC Rev 01 ISSUE DATE : 05/10/2020...
  • Page 2 Your Arada stove is built to the highest standard of craftsmanship using the best materials and the most modern equipment available. It is a highly efficient and sophisticated piece of machinery and when properly installed and operated it should provide a lifetime of heating satisfaction.
  • Page 3: Table Of Contents

    LAGOM Stove User Guide Contents 1 Identifying your stove 1.1 Identifying parts & terminology of your stove—External..….. 1.2 Identifying parts & terminology of your stove—Internal ……. 2 Additional installation information 2.1 Stove clearance dimensions……………………………………… 2.2 Corner installation dimensions …………………………………… 2.3 Floor protection dimensions ………………………………………...
  • Page 4 8.10 Fire door handle ……………………………………………….. 8.11 Storage cupboard/compartment………………………………. 9 How heat is delivered by your stove 9.1 Radiant heat …………………………………………………….. 10 Care for your Arada stove 10.1 Liners / firebricks ……………………………………………… 10.2 Throat plate …………………………...………………………. 10.3 Fire door seal ……………………………………………………...
  • Page 5: Identifying Your Stove

    LAGOM Stove User Guide 1 Identifying your stove 1.1 Identifying parts & terminology of your stove—External Top Flue Outlet Hot Glove x1 (Packed Inside Fire Door Stove) Assembly Fire Door Handle Socket Air Control Rear Flue Outlet (Behind Knock Out Rear Cover) (NOTE : Top &...
  • Page 6: Identifying Parts & Terminology Of Your Stove-Internal

    LAGOM Stove User Guide 1.2 Identifying parts & terminology of your stove—Internal Firebox Liners Flue Spigot (Sides & Rear) (Can be interchanged with rear hotplate) Grate Area Fire Door Glass Fuel Retainer Incorporated into grate Ash Pan Location (Below grate area)
  • Page 7: Additional Installation Information

    LAGOM Stove User Guide 2 Additional Installation Information PLEASE NOTE : This additional information is to be read in addition to BK545 ‘Dry Stove Installation Guide’ 2.1 Stove clearances dimensions Minimum Distance To Combustible Materials 100mm 100mm 800mm 1200mm BK 746 Specific...
  • Page 8: Corner Installation Dimensions

    LAGOM Stove User Guide PLEASE NOTE : This additional information is to be read in addition to BK545 ‘Dry Stove Installation Guide’ 2.2 Corner Installations dimensions Corner installation clearances to combustible materials 100mm 257mm For alcove installation The ceiling or shelf above...
  • Page 9: Stove Dimensional Drawing

    LAGOM Stove User Guide 2.4 Stove dimensional drawing External Air Connection Ø 125mm Secondary & Primary Air Control BK 746 Specific Page 9...
  • Page 10: External Air Supply Connections

    125mm diameter in metal construction is recommended. 2.6 Rear flue spigot connection The default factory fitment for the Lagom, is for the flue spigot (150mm diameter) to be fitted to the top outlet. Provision for a rear fitted flue can be accessed via the knock-out cover in the rear panel of the appliance (see above picture).
  • Page 11: Warnings

    This will result in an over firing situation and will lead to severe damage to the stove and flue system. Ignoring the warnings could lead to damage/injury to persons and/or property. Arada Ltd will not be responsible for any consequential or incidental loss or injury however caused. BK 746 Specific...
  • Page 12: Health And Safety

    LAGOM Stove User Guide 3.2 Health and Safety Please consult Health and Safety Guidelines for advice on handling heavy and/or large items. 4 Recommended fuels 4.1 Wood As a natural and renewable fuel, wood is the first choice for burning, however burning wood requires a little effort and planning.
  • Page 13: Before Using Your Stove

    LAGOM Stove User Guide 5 Before using your stove Arada stoves are designed to be operated with the fire door(s) closed at all times, apart from refuelling (when alight) or cleaning (when cold). Never leave the appliance unattended for an extended length of time with the door open.
  • Page 14: Air Inlet Controls

    LAGOM Stove User Guide 6 Air inlet controls 6.1 Air Inlet Your stove requires air to function. This enters the appliance via the circular duct on the under side of the stove. Depending upon installation, this circular duct can also act as the connection point for the direct air feed / ducting requirements.
  • Page 15: Air Control

    LAGOM Stove User Guide 6.1.2 Air control lever The control has an internal sliding plate with slots housed inside the body of the appliance and is located centrally below the fire door. Pulling the control lever out achieves the fully open position, see Figure 1. Pushing the control lever in will reduce the air or shut down the stove as shown in Figure 2.
  • Page 16: Lighting Your Stove

    LAGOM Stove User Guide 7 Lighting your stove 7.1.1 Smoke control areas Please check whether your dwelling is located in a smoke control area before installation or use. Please check with your local authority or https://www.gov.uk/smoke-control-area-rules. 7.1.2 Fuel overloading The maximum amount of fuel specified in this manual should not be exceeded. Overload- ing can cause excess smoke.
  • Page 17: Refuelling

    LAGOM Stove User Guide 7.3 Refuelling In order to prevent smoke escaping into the room when refuelling, please follow the procedure below: Approximately 5-10 seconds before opening the fire door, open the air control fully and then only slightly open the fire door. Wait a few seconds for the exhaust gas to get sucked into the chimney and only then fully open the door.
  • Page 18: Refuelling On To A Low Fire Bed

    LAGOM Stove User Guide STOP USING THE APPLIANCE IF YOU SMELL FUMES OR SEE SMOKE ESCAPING. If fume emission does persist, the following immediate actions should be taken: Open doors and windows to ventilate room.  Let the fire die or extinguish and safely dispose of fuel from the appliance.
  • Page 19: Further Information For All Stove Owners

    LAGOM Stove User Guide 8 Further information for all stove owners 8.1 Reduced burning (Slow Combustion) When wood is burnt slowly in a closed appliance (e.g.: air controls at the minimum setting), it produces moisture and tar which will create condensation and deposits in the chimney.
  • Page 20: Ash Removal

    You can find a complete list of spares and consumables such as liners, grate and throat plates, as well as items to enhance its visual appearance and efficiency such as stove paint and rope kits. It is worth noting that the fitting of non-official Arada parts to your stove will invalidate its guarantee. 8.7 Classification All Lagom stoves are classed as intermittent operation.
  • Page 21: Adverse Weather Conditions

    LAGOM Stove User Guide 8.8 Adverse weather conditions If due to adverse weather conditions your stove does not operate correctly and causes the stove to emit smoke, do not treat it as a nuisance. This smoke will indicate that carbon monoxide is being emitted into the room.
  • Page 22: How Heat Is Delivered By Your Stove

    Heat 9.1 Radiant heat All Arada stoves radiate heat into the room. The radiated heat is most intense at the front of the stove, especially through the door glass and less intense the further you move away from the stove.
  • Page 23: Care For Your Arada Stove

    Use the reverse order for re-assembly 10.2 Throat plate The Lagom stove model contains two throat plates, the upper is metal and the lower above the fire bed is manufactured from ceramic clay. The throat plate can be removed from the stove by following the instructions above.
  • Page 24: Fire Door Seal

    LAGOM Stove User Guide 10.3 Fire door seal The rope seal around the edges of the main fire door should also be checked. Look for signs of fraying, peeling away or the ends not meeting. If the rope is unable to create a good seal with the stove body it should be replaced.
  • Page 25: Further Resources / Reading

    However if you have any queries, doubts or would like further advice please do not hesitate to speak to your Arada dealer or call us. You will find our contact details below, as well as a list of resources where you can discover more information about your stove and associated articles.
  • Page 26: Guarantee

    LAGOM Stove User Guide 12 Guarantee When you buy an Arada stove, you are not only buying a first class appliance, you are receiving a commitment from us to look after you and your appliance. 12.1 Guarantee If any part of the main body of the stove fails due to a manufacturing or material defect during the guarantee period that applies in respect of the relevant stove (as set out below), Arada will, at its sole discretion, repair or replace your Arada stove for no charge.
  • Page 27 11. The guarantee is only valid where any spare parts used are supplied by Arada or an approved Arada dealer. The use of spares other than those supplied by Arada Limited shall invalidate the guarantee.
  • Page 28: General

    LAGOM Stove User Guide 12.3 General Our guarantee is offered as an addition to your statutory rights and will not effect your statutory rights. You can obtain information about your legal rights from Trading Standards offices or a Citizens Advice Bureau.
  • Page 29: Technical Data

    LAGOM Stove User Guide 13 Technical Specification TECHNICAL DATA Lagom Height (mm) Width (mm) (Across Canopy) Depth (mm) (Inc. Handle Boss) Height to Centre of Rear Flue (mm) Depth from back to Flue Centre Flue Diameter (mm) 152 (6”) 100 (Rear) Minimum Distance to Combustible Materials—...
  • Page 30: Notes

    LAGOM Stove User Guide 14 Notes : Page 30 BK 746 Specific...