  • Page 1 SUSPENDED WARM AIR HEATERS EOLO B modulating pre-mixed versions AE and AC...
  • Page 2 SYSTEMA S.p.A. EOLO BLULINE IMPORTANT!! Read carefully this manual before starting up the system. In order to improve the product, Systema reserves the right to modify the contents without any notice. SYSTEMA S.p.A. Via Antonio Ceccon, 3 Loreggia C.A.P. 35010 PADOVA - ITALIA ISO 9001:2008 Tel.
  • Page 3: Table Of Contents

    SYSTEMA S.p.A. EOLO BLULINE SUMMARY GENERAL RULES ........... . .5 GENERAL WARNINGS .
  • Page 4 SYSTEMA S.p.A. EOLO BLULINE GAS PIPES ............34 EQUIPMENT CONNECTION .
  • Page 5: General Rules

    It is compulsory to follow the information indicated in this manual, particularly for what concerns the secu- rity rules. Systema disclaims any liability for any direct or indirect personal or physical injury resulting from failure to follow the instructions in this manual.
  • Page 6 SYSTEMA S.p.A. EOLO BLULINE The generator must be checked by qualified personnel before the start up in order to verify: - that the data of the gas and electrical power networks correspond to those standard written in this ma- nual - the correct creation and functioning of the gas exhaust pipe and of the combustion air intake...
  • Page 7: Construction Features

    SYSTEMA S.p.A. EOLO BLULINE CONSTRUCTION FEATURES EOLO BLULINE is the new range of hanging hot air generators with high performances. The name BLULINE represents their high performances, improved in many aspects. FUEL CONSUMPTION REDUCTION The modulation of the thermal flow of the burner in manual or auto- matic, allows to provide thermal power in relation to climate conditions.
  • Page 8: Technical Data

    SYSTEMA S.p.A. EOLO BLULINE TECHNICAL DATA EOLO BLULINE MODEL BL 15 BL 25 BL 35 BL 45 BL 55 BL 65 BL 85 BL 100 Nominal kW (Hi) Maximum thermal 93,1 92,9 93,1 93,0 93,0 92,0 92,0 Efficiency capacity 14,9 20,4...
  • Page 9: Main Components

    SYSTEMA S.p.A. EOLO BLULINE MAIN COMPONENTS 1.4.1 Burner MODELLO EOLO BL PREMIX PREMIX PREMIX PREMIX PREMIX PREMIX PREMIX PREMIX Burner 15/25* 15/25 * 35 * 65 * 85/100 * 85/100* Burner code * Technical specifications and part numbers of the burner, see section 1.8 on page 22 Tab 1.2...
  • Page 10: Performance Diagrams Ac Fans - Mv Fans Referring Table 1.4.3

    SYSTEMA S.p.A. EOLO BLULINE 1.4.4 Performance diagrams AC Fans - MV fans referring table 1.4.3 Fan 9-9 1V kW 0,123 P6 1F Flow Characteristics - Delivery Head Fan 9-9 1V kW 0,123 P6 1F Flow Characteristics - Power Fan 10-10 1V kW 0,373 P6 1F Flow Characteristics - Delivery Head Fan 10-10 1V kW 0,373 P6 1F Flow Characteristics - Power Rev.
  • Page 11 SYSTEMA S.p.A. EOLO BLULINE Fan 12-9 1V kW 0,570 P6 1F Flow Characteristics - Delivery Head Fan 12-9 1V kW 0,570 P6 1F Flow Characteristics - Power Fan 12-12 1V KW 0,570 P6 1F Flow Characteristics - Delivery Head Fan 12-12 1V KW 0,570 P6 1F Flow Characteristics - Power...
  • Page 12: Performance Curves Of Eolo Ac - Fans Nicotra

    SYSTEMA S.p.A. EOLO BLULINE 1.4.5 Performance curves of EOLO AC - Fans NICOTRA 1.4.5.a Fans performance curves 9/7 NICOTRA for Eolo 15-25 (230V - 50Hz) Type: Type: DDM 9/7 DDM 9/7 Watt: Watt: Amp Max: Amp Max: γ γ Air Density ( Air Density ( ): 1.20 kg/m...
  • Page 13: Fans Performance Curves 10/10 Nicotra For Eolo 35 And 65 (230V - 50Hz)

    SYSTEMA S.p.A. EOLO BLULINE 1.4.5.b Fans performance curves 10/10 NICOTRA for Eolo 35 and 65 (230V - 50Hz) Type: Type: DDM 10/10 DDM 10/10 Watt: Watt: Amp Max: Amp Max: γ γ Air Density ( Air Density ( ): 1.20 kg/m ): 1.20 kg/m...
  • Page 14: Fans Performance Curves 10/10 Nicotra For Eolo 35 And 65 (230V - 60Hz)

    SYSTEMA S.p.A. EOLO BLULINE 1.4.5.c Fans performance curves 10/10 NICOTRA for Eolo 35 and 65 (230V - 60Hz) γ Type: DDM 10/10 Watt: Amp Max: Air Density ( ): 1.20 kg/m Motor: E6G3608 Volt: 230 1~ Prot.: IP 55 Installation type "B": free inlet, ducted outlet Test nr.:...
  • Page 15: Fans Performance Curves For 12/9 Nicotra For Eolo 45 And 85 (230V - 50Hz)

    SYSTEMA S.p.A. EOLO BLULINE 1.4.5.d Fans performance curves for 12/9 NICOTRA for Eolo 45 and 85 (230V - 50Hz) γ Type: DD 12/9 Watt: 735/1120 Amp Max: 7.59 Air Density ( ): 1.20 kg/m Motor: 14195C Volt: 230 1~ Prot.: IP 20 Installation type "B": free inlet, ducted outlet...
  • Page 16: Fans Performance Curves 12/12 Nicotra For Eolo 55 And 100 (230V - 60Hz)

    SYSTEMA S.p.A. EOLO BLULINE 1.4.5.e Fans performance curves 12/12 NICOTRA for Eolo 55 and 100 (230V - 60Hz) γ Type: DD 12/12 Watt: Amp Max: Air Density ( ): 1.20 kg/m Motor: E0A1702F Volt: 230 1~ Prot.: IP 20 Installation type "B": free inlet, ducted outlet Test nr.:...
  • Page 17: Fans Performance Curves 12/12 Nicotra For Eolo 55 And 100 (230V - 50Hz)

    SYSTEMA S.p.A. EOLO BLULINE 1.4.5.f Fans performance curves 12/12 NICOTRA for Eolo 55 and 100 (230V - 50Hz) γ Type: DD 12/12 Watt: Amp Max: Air Density ( ): 1.20 kg/m Motor: E0A1702F Volt: 230 1~ Prot.: IP 20 Installation type "B": free inlet, ducted outlet Test nr.:...
  • Page 18: Dimensions Eolo Bluline Ae - Helicoidal Fans Version

    SYSTEMA S.p.A. EOLO BLULINE DIMENSIONS Eolo BLULINE AE - helicoidal fans version Fig 1.9 EOLO AE EOLO BL 15 AE 25 AE 35 AE 1095 45 AE 1145 55 AE 1285 65 AE 1050 1440 85 AE 1000 1150 1600 100 AE...
  • Page 19: Dimensions Eolo Bluline Ac - Centrifugal Fans Version

    SYSTEMA S.p.A. EOLO BLULINE DIMENSIONS Eolo BLULINE AC - Centrifugal fans version Fig 1.10 EOLO BL 15 - 25 AC 1020 25 AC 1020 35 AC 630 1095 600 1020 45 AC 780 1145 715 1150 55 AC 780 1285 715...
  • Page 20: Exploded View

    SYSTEMA S.p.A. EOLO BLULINE EXPLODED VIEW 1.7.1 Eolo BLULINE AE helicoidal version Fig 1.11 1.7.2 Eolo BLULINE AC centrifugal series Fig 1.12 Rev. 04GB1410...
  • Page 21 E. BL 35 AE/AC 80VIPA5011 E. BL 15-25 AC 04CNCO2702 E. BL 45 AE/AC 80VIPA5012 E. BL 35 AC 04CNCO2703 15 Pre-mix burner brand "SYSTEMA" E. BL 55 AE/AC 80VIPA5013 E. BL 45 AC 04CNCO2700 E. BL 65 AE/AC 80VIPA5014 7b Fans hood E.
  • Page 22: Burner Exploded View

    SYSTEMA S.p.A. EOLO BLULINE BURNER EXPLODED VIEW Fig 1.13 Burner exploded view Tab 1.8 Burner fig. 1.13 Description Model Cod. Description Model Cod. E. BL 15 AE/AC 80VIPA5016 M4 screws venturi fixing 10WSSR2060 E. BL 25 AE/AC 80VIPA5010 E. BL 15-25-35-45 -55-65...
  • Page 23: Electrical Plant

    SYSTEMA S.p.A. EOLO BLULINE ELECTRICAL PLANT The electrical plant must be realized according to MAIN ELECTRONIC BOARD the national and local laws. SCP674V010 GENERAL CHA- The electrical plant must be adapted to the maxi- RACTERISTICS mum power absorbed by the equipment indicated Electrical supply: .....230 Vac +/- 10%...
  • Page 24: Auxiliary Control Fan

    SYSTEMA S.p.A. EOLO BLULINE To reset the operation, delete the alarm condition: AUXILIARY CONTROL FAN 2.1.3 a) By performing a proper maintenance to fix it. AUXILIARY CONTROL FOR THE SUMMER VEN- (This is to ensure the closure of the contact J7C).
  • Page 25: Display Indications Scp674V010

    Burner off ELECTRICAL DIAGRAM 230 VAC MONOPHASE EOLO BLULINE AE-AC ATTENTION!! EOLO WORKS WITH CONTROL PANELS SUPPLIED BY SYSTEMA. The manufacturer declines any liability for any damage caused by improper installation or improper use and / or misuse of the equipment, or from an installation with board not supplied by Systema.
  • Page 26: Schema Elettrico Alimentazione Trifase 400 V 50 Hz

    SYSTEMA S.p.A. EOLO BLULINE SCHEMA ELETTRICO ALIMENTAZIONE TRIFASE 400 V 50 Hz CABLE CONNECTION Pos. Description ......Code Cable connection double thermostat .
  • Page 27: On/Off Control Board Connection Diagram

    SYSTEMA S.p.A. EOLO BLULINE ON/OFF CONTROL BOARD CONNECTION DIAGRAM Connect electric power supply, commands and remote signs as follows Fig 2.3 DISPL BLOWER LED_FA LED_BLK LED_TA SCP674V010 (REV.01) FUSE - F4 FUSE - F3 F1-F2=5AF F3-F4=3.5AF 0 - 5 V. F1 FUSE...
  • Page 28: Connection Diagram Of Combustion Unit And The Inet Network Control Board

    SYSTEMA S.p.A. EOLO BLULINE CONNECTION DIAGRAM OF COMBUSTION UNIT AND THE INET NETWORK CONTROL BOARD FOR A SINGLE UNIT LEGEND INET CONNECTIONS (all models) Power supply (230VAC 50/60Hz) Alarm relay 3(1) A 230Vac (only for preset mod- els) C-OP External probe (only for preset models)
  • Page 29: Connection Diagram Of The Electric Control Board Of Inet Network With The Zone Probes For One Or More Combustion Groups

    SYSTEMA S.p.A. EOLO BLULINE CONNECTION DIAGRAM OF THE ELECTRIC CONTROL BOARD OF INET NET- WORK WITH THE ZONE PROBES FOR ONE OR MORE COMBUSTION GROUPS LEGEND PROBES CONNECTIONS Fig 2.3 P1-P2-P3-P4 INET from 1 to 16 units - 1 Thermal zone...
  • Page 30: Connection Diagram Combustion Unit And Inet Network Control Board From 2 To

    External probe (only for preset models) +A, -B, S BUS INET Network connections ATTENTION: EOLO WORK EXCLUSIVELY WITH ELECTRICAL PANELS SUPPLIED BY SYSTEMA S.P.A.; the manufacturer declines all the responsibility in case of any damage caused by an 3 4 P1...
  • Page 31: Configuration Of The Board Inside The Machine Scp674V010 For Functioning With Several Combustion Units And The Inet Control Board

    SYSTEMA S.p.A. EOLO BLULINE 2.7.1 Configuration of the board inside the machine SCP674V010 for functioning with se- veral combustion units and the INET control board Using the switch SW2 it is possible to assign an address to each network interface. The network control recognize the remote units by the number with which they have been codified, therefore it is necessary to avoid to give the same number to two different remote units, in order to exclude conflict situations with the consequent shutdown of the heating installation.
  • Page 32: Connection Diagram Combustion Units And Ce On/Of Control Board Code

    SYSTEMA S.p.A. EOLO BLULINE CONNECTION DIAGRAM COMBUSTION UNITS AND CE ON/OF CONTROL BOARD code 04CEQU1204 Control board with thermostat, reset, ON/OFF switch to control n.01 combustion unit DISPL BLOWER Configurationcontrol board SCP674V010 LED_FA LED_BLK JP1 and JP2 = CLOSED on A LED_TA SCP674V010 (REV.01)
  • Page 33: Connection Diagram Combustion Units And Ce On/Off Control Board Code 04Cequ1202 And 04Cequ1203

    SYSTEMA S.p.A. EOLO BLULINE CONNECTION DIAGRAM COMBUSTION UNITS AND CE ON/OFF CONTROL BOARD code 04CEQU1202 and 04CEQU1203 Control board with thermostat, reset, ON/OFF switch to control n.01 combustion unit DISPL Configurationcontrol board SCP674V010 BLOWER JP1 and JP2 = CLOSED on A...
  • Page 34: Gas Pipes

    SYSTEMA S.p.A. EOLO BLULINE GAS PIPES EQUIPMENT CONNECTION Gas supply pipes have to be realized in compliance with national and local rules. The dimensioning of the tubes and of the eventual pressure reducers/gears has to be such as to ensure the correct working of the equipments. The materials used must comply with the existing national and local laws.
  • Page 35: Installation

    SYSTEMA S.p.A. EOLO BLULINE INSTALLATION In order to reach the maximum performance of the han- ging hot air generators “EOLO” we suggest you to re- spect the following rules/laws: - Define the installation considering the type of work, the priorities zones to be heated and the absorption walls (windows, doors, gates etc.) see fig.
  • Page 36: Wall Installation Examples

    SYSTEMA S.p.A. EOLO BLULINE WALL INSTALLATION EXAMPLES It is possible to fix Eolo BLULINE on the building’s wall using one of the solutions shown on the following figures.. Fig.4.6 Example of wall fixing with universal brackets ATTENTION!! IN ORDER TO INSTALL A HANGING EOLO, PLEASE SPECIFY THIS CONFIGURATION WHEN YOU ORDER THE DEVICE.
  • Page 37: Examples Of Installations Of Eolo At A Wall With Rorating Bracket (Optional)37

    SYSTEMA S.p.A. EOLO BLULINE EXAMPLES OF INSTALLATIONS OF EOLO AT A WALL WITH RORATING BRACKET (OPTIONAL) It is possible to fix to the wall of the building the generator Eolo BLULINE (ONLT THE MODELS 15 - 25 - 35 - 45 - 55 AE) using one of the solutions illustrated in the following figures.
  • Page 38: Centrifugal Installation Example

    SYSTEMA S.p.A. EOLO BLULINE CENTRIFUGAL INSTALLATION EXAMPLE On the following figure it is described an example of installation of a centrifugal Eolo, installed inside and canalized. The air intake is from outside and from inside with possibility to regulate the internal/external air mixture.
  • Page 39: Exhaust And Suction Ducts

    SYSTEMA S.p.A. EOLO BLULINE EXHAUST AND SUCTION DUCTS Type C53 Type B23 Type B23 Maximum pipe length Maximum pipe length Maximum pipe length 6+6 meters Ø100 mm 8 meters Ø100 mm 8 meters Ø100 mm Type C33 Type C33 Type C13...
  • Page 40: Separate Wall Discharge Type C13

    SYSTEMA S.p.A. EOLO BLULINE SEPARATE WALL DISCHARGE TYPE C13 Pos. Description Code Q.ty 1 Wall fumes terminals Ø100 mm with hole cover rosette 04CNTE0445 2 Wall air terminals Ø 100 mm with hole cover rosette 04CNTE0446 3 Stainless steel joint flexible/rigid pipe F Ø 100 mm 00CNGI2542 4 Stainless steel flexible air pipe Ø...
  • Page 41: Separate Roof Discharge Type C33

    SYSTEMA S.p.A. EOLO BLULINE SEPARATE ROOF DISCHARGE TYPE C33 Pos. Description Code Q.ty Roof terminals Ø 100mm with: Upper border 00CNTE0442 Lead flashing Hole cover rosette 2 90° bend M/F Ø 100 04CNCU0532 3 Stainless steel joint flexible/rigid pipe F Ø 100 mm 00CNGI2542 4 Stainless steel flexible air pipe Ø...
  • Page 42: Coaxial Roof Discharge Type C33

    SYSTEMA S.p.A. EOLO BLULINE COAXIAL ROOF DISCHARGE TYPE C33 Pos. Description Code Q.ty 1 Coaxial roof terminal Ø 150 mm 00CGKI2515 2 Upper border 00CNCO2676 3 Lead flashing 00CNCO2673 4 Hole cover rosette 02CNMA3002 5 Splitter 01CVSD3002 6 90° bend M/F Ø 100 04CNCU0532 7 Stainless steel joint flexible/rigid pipe F Ø...
  • Page 43: Testing And Equipment Start Up

    SYSTEMA S.p.A. EOLO BLULINE TESTING AND EQUIPMENT START UP PRELIMINARY OPERATIONS Before starting Eolo BLULINE, we suggest to check the following: 1) Control the correct electrical connection between burner, control panel and the electrical supply net. 2) Verify that the equipment are provided for the type of gas available (eventually refer to paragraph 6.5 on fuel change), verify the net pressure (see tab 6.4 on page 48) and open gas: verify that the gas flow...
  • Page 44: Regulations On Generators With 848 Sigma Valve

    SYSTEMA S.p.A. EOLO BLULINE 6.3.1 Regulations on generators with 848 Sigma valve 1) Place the manometer on point (6) of the gas valve for the detection of the gas outlet pressure. 2) Use the fumes analyzer to verify if the combustion values are cor- rect and if they correspond in paragraphs 8.
  • Page 45: Regulations On Generators With 822 Nova Mix Valve

    SYSTEMA S.p.A. EOLO BLULINE 6.3.2 Regulations on generators with 822 Nova Mix valve 1) place the manometer on point (2) of the gas valve to detect the ou- tlet gas pressure. 2) use the fumes analyzer to verify that combustion values are correct and correspond in paragraphs 8.
  • Page 46: Air Mixer

    SYSTEMA S.p.A. EOLO BLULINE 6.3.3 Air mixer The air-gas mixer placed upstream the burner fan, provide the burner with the right air and gas volume. The air re- gulation mustn’t be modified except of constructor indication. Pos. Description Air/gas mixer Gas inlet...
  • Page 47: Fuel Change

    SYSTEMA S.p.A. EOLO BLULINE FUEL CHANGE The gas/nozzle change must be performed by technical qualified personnel in compliance with the security laws and with this manual. The constructor disclaims any responsibility in case of damages deriving from wrong transforma- tion or improper and/or incorrect appliance use.
  • Page 48: Nozzles

    SYSTEMA S.p.A. EOLO BLULINE NOZZLES EOLO BLULINE MODEL BL 15 BL 25 BL 35 BL 45 BL 55 BL 65 BL 85 BL 100 methane G20 mbar Supply line pressure butane G30 mbar propane G31 mbar methane G20 4,50 5,00 5,50...
  • Page 49: Thermal Flow Manual Regulation

    ATTENTION PWM VALUES, WHICH HAVE BEEN SET BY THE CONSTRUCTOR, CANNOT BE CHANGED. They can be modified only by company Systema's specialized personnel. EOLO BL 15 EOLO BL 25 EOLO BL 35...
  • Page 50: Warranty

    WARRANTY COVER AND VALIDITY 1) The warranty is limited to the faults of the heater components supplied by SYSTEMA. In the event of a fault of components or in case of production defect, SYSTEMA shall repair or replace faulty parts ex- works free of charge.
  • Page 51: Setting Aside

    SYSTEMA S.p.A. EOLO BLULINE SETTING ASIDE ATTENTION! All disconnection operations must be preformed by authorized technical personnel! If the appliance is to be set aside for a lengthy period of time, the following operations must be performed: Turn the main switch to “0” and disconnect the appliance from the power supply.
  • Page 52 To continually improve the products, SYSTEMA S.p.A. reserves the right to alter the characteristics with- out prior notice.