Pic Testing And Verification - Allied Telesis AT-AR020 PRI E1/T1 Hardware Reference Manual

Port interface card
Hide thumbs Also See for AT-AR020 PRI E1/T1:
Table of Contents

Advertisement

26
Figure 15: Example output from the show system command for a switch or router with PICs installed
Router System Status
Board
ID
Bay Board Name
--------------------------------------------------------------------------------
Base
62
IC Module
40
0
IC Module
38
1
MAC
67
--------------------------------------------------------------------------------
Memory -
DRAM : 16384 kB
--------------------------------------------------------------------------------
SysDescription
CentreCOM AR720 version 1.8.1-00 08-Sep-1999
SysContact
David Johns, ext 8331
SysLocation
Laboratory, First Floor, Head Office Building
SysName
LAB
SysUpTime
250074 ( 00:41:40 )
Software Version: 1.8.1-00 08-Sep-1999
Release Version : 1.8.1-00 08-Sep-1999
Patch Installed : NONE
Territory
: europe
Help File
: help.hlp
Boot configuration file: load.cfg (exists)
Current configuration: load.cfg
Security Mode
: Disabled
Warning (248283): No patches found.

PIC Testing and Verification

There are several ways to check that a PIC is installed and operating correctly.
First, check that the switch or router has recognised the card. Turn on the
switch or router, and enter the following command to display system
information
(Figure
15):
show system
AR720
AR022 PIC Eth
AR023 PIC Sync
AR012 CMAC
FLASH :
The first part of the display shows details of cards installed in the switch or
router. There should be one entry for the switch's or router's base card and one
entry for each PIC installed. Both the serial number and the part name should
also be displayed.
If there is no entry for a PIC, then the boot process has not correctly detected
the presence of the PIC. The most likely cause is that the connector on the PIC
is not plugged into the PIC slot on the base card correctly. Repeat the
installation process, inserting the PICs carefully into the lowest numbered bays
first, then tightening the screws firmly. Use the show system command from
the Operation chapter of the Software Reference for your switch or router. If the
display is still not correct, contact your authorised Allied Telesyn distributor or
reseller.
If you have any difficulty with the PIC at any time, contact your authorised
Allied Telesyn distributor or reseller and quote the serial numbers of both the
base CPU card and the PIC. These numbers are printed on the cards, and can
Time 17:10:06 Date 25-Sep-2000.
Rev
Serial number
M1-0
6845218
M2-0
6844595
M1-1
6844715
M2-0
33636409
4096 kB
Port Interface Card
C613-03023-00 REV J

Advertisement

Table of Contents
loading

This manual is also suitable for:

At-ar021 (s) bri-s/tAt-ar021 (u) bri-uAt-ar022 ethAt-ar023 synAt-ar024 asyn4At-ar026 4eth ... Show all

Table of Contents