TECHNICAL FEATURES

Thermal power – output
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
Burner with CE marking in conformity with EEC directives: EMC89/336/EEC, Low Voltage 73/23/EEC,
Machines 98/37/EEC and Efficiency 92/42/EEC.
For use on hot air generator the burner must be fitted with control box type 539SE.
The burner meets protection level of IP 40, EN 60529.
1 – Return line
2 – Suction line
3 – Gauge connection
4 – Pressure regulator, 2
5 – Vacuum gauge connection
6 – Hydraulic jacks with air-damper
7 – Combustion head adjustment screw
8 – Lock-out lamp and reset button
9 – Flange with insulating gasket
10 – Regulation pressure, 1
11 – Economizer
1716
G5 I R
CODE
19 / 26 – 60 kW
Gas oil, max. viscosity at 20 °C: 6 mm
Single phase, 230 V ± 10%
Run current 0.75 A – 2850 rpm – 298 rad/s
4 m F
Secondary 8 kV – 16 mA
Pressure: 7 – 15 bar
0.185 kW
S7343
nd
stage
st
stage
3745610
1.6 / 2.2 – 5 kg/h
~
Fig. 1
EQUIPMENT
Quantity
2
Flexible pipes with nipples
1
Flange with insulating gasket
4
Screws and nuts for flange
1
Hinge
1
Screw with two nuts for flange
1
External probe
1
7 pin plug
1
4 pin plug
1
GB
456T1
TYPE
2
/s (1.5 °E)
50Hz