7 | Maintenance
7 Maintenance
WARNING
Risk of injury due to electric current
Conductive components can cause serious injury or death.
w
De-energise all components before you begin working.
WARNING
Risk of injury due to loose compressed air lines and connectors
Loose compressed air lines and connectors can cause severe injury.
w
Before starting any work, depressurise all components.
7.1 Maintenance Plan
Clean the TAIFUN-CLEAN unit whenever contaminated, however at least every
4 weeks.
Type of service
Clean TAIFUN-CLEAN unit
Table 5: Maintenance plan TAIFUN-CLEAN
7.2 Maintenance of the Rotating Nozzles
If used as intended, the TAIFUN-CLEAN rotating nozzle is maintenance-free.
u
Check firm seating of the rotating nozzles in the TAIFUN-CLEAN device using only
the special mounting tool TCK7
Type of service
Check rotating nozzles
Table 6: Maintenance plan rotating nozzles
1. Remove the cover disc, if present, by loosening the screws.
2. Set the mounting tool TCK7 on the rotating nozzle.
3. Turn the mounting tool TCK7 in a clockwise direction, until the rotating nozzle is
hand-tight.
4. If necessary, mount the cover disc again.
28
Service interval
As necessary, at least every 4 weeks
(}
).
Fig. 7, p. 29
Service interval
As necessary, at least every 4 weeks
TAIFUN-CLEAN 014/015/016
Need help?
Do you have a question about the TAIFUN-CLEAN 014 and is the answer not in the manual?