1.Description
Clip T Series is one of the most compact and cheapest thermal
imager attachment for sights on the market, which is mainly used with
day riflescope and low cost, low power consumption and miniaturization.
2. Components
1
1. Objective Lens
2. Power (P) Button
2
5
3. Type-C Interface
3
4. Menu (M) Button
4
5. Battery Compartment
6. Eyepiece Locking Ring
7. Eyepiece Interface
6
7
3. Features
12µm thermal imaging detector
l
High image quality
l
The most compact size
l
Ultra light weight
l
Low power consumption and long endurance
l
HD resolution OLED Display
l
IP67 Rating
l
4. Battery Installation
Remove the battery cap by unscrewing it counter clockwise
l
Insert a CR123 with positive pole inwards
l
Return battery cap into housing, screw clockwise until tight
l
Tips:
Avoid removing the O shape seal ring.
Ø
Notice the poles of battery placed in right directions.
Ø
5.Mounting Clip T on a DaylightScope
Before installing Clip T onto your daylight device, the following
preparations should be made:
Select an adaptor fixture (9) with an insert of the required diameter
l
depending on the outer diameter size of the objective lens of your
daylight device.
Prepare a thread adapter insert (8) that can match with the thread
l
interface of Clip T eyepiece and metal adaptor fixture.
7
8
9
10
11
Insallation
Install the threaded adapter insert (8) to Clip T by rotating clockwise
l
along the thread.
Rotate the eyepiece locking ring (6) counterclockwise to lock the
l
adapter insert (8).
Install the threaded insert (8) fully into the adapter fixture (9).
l
Install fully the adapter fixture (9) with Clip T onto the objective lens
l
(10) of your daylight device.
Pull the handle (11) on the adapter fixture (9) to lock it firmly on your
l
daylight device. Check that the adapter fixture (9) is snugly fitted onto
the objective lens (10) .
If there is space or if the lever cannot reach the locking position, adjust
l
the locking screw with the hex-nut wrench to ensure that the adapter
fits tightly the objective lens.
Tips:
Clip may be installed in wrong position while tighten on screw thread,
Ø
change its position by adjust eyepiece locking ring.
The eyepiece interface thread (7) of Clip T series is M30*1.0;
Ø
A thread adapter ring with M52*0.75 thread interface will be presented
Ø
in the package of Clip T;
6. Menu/Status Bar Icons
Whitehot
Blackhot
Redhot
Color
Displaylightness
ManualCalibration
M
AutomaticCalibration
A
USBmode
BatteryIndicator
7. Operations
7.1 Switch On/Off
Press and hold the P button(2) to turn on the device. Waiting for 3
seconds to enter the home interface.
Press and hold the P button (2) until the shutdown countdown is 0,
release the button to turn off the device.
7.2 Standby Mode
Press and hold P button(2) until the countdown appears, release the
button within 3s countdown to active the standby mode.
Short press P button(2) again to exit standby mode.
7.3 Status Bar
In the home interface, there are system information hints at the bottom of
the screen including: Palette, Screen Brightness, Calibration mode,
Battery status etc.

Advertisement

loading

Summary of Contents for InfiRay Clip T Series

  • Page 1 1.Description 6. Menu/Status Bar Icons 5.Mounting Clip T on a DaylightScope Clip T Series is one of the most compact and cheapest thermal Whitehot Before installing Clip T onto your daylight device, the following imager attachment for sights on the market, which is mainly used with...
  • Page 2 7.4 Calibration 7.7 Type-C Mode Specifications In the home interface, short press the P button(2) for shutter calibration. In the home interface, while connected with Type C cable, press and hold Model CTP13 the M button(4) and meanwhile quickly press P button(2) five times to 7.5 Image Movement activate Type C Mode for updating firmware.