Download Print this page

Gross Only=Xxx; Low Wt - Cardinal 205-DAC Installation Manual

Digital to analog converter

Advertisement

CALIBRATION OF ANALOG OUTPUT, CONT.

1. GROSS ONLY=XXX

The output can be set to follow the Gross weight only or the displayed weight (gross or net).
With the 2xx-DAC SETUP MENU displayed the current setting for the GROSS ONLY=
parameter will be shown. Note that XXX is the current value. If the setting displayed is
acceptable, proceed to the next setup parameter.
Otherwise, press the 1 key and then the ENTER key. The display will change to show the
following screen.
GROSS ONLY=XXX
YES
Press the YES or NO (on the soft keys) and then the ENTER key to save the new setting and
return to the 2xx-DAC SETUP MENU
GROSS ONLY=YES
DAC output is Gross Weight Only
2. LOW WT= XXXXXX
This is the weight value which outputs zero volts (or 4 mA) from the DAC.
With the 2xx-DAC SETUP MENU displayed the current setting for the LOW WT= parameter
will be shown. Note that XXXXXX is the current value. If the setting displayed is
acceptable, proceed to the next setup parameter.
Otherwise, press the 2 key and then the ENTER key.
following screen.
LOW WT=XXXXXX
Using the numeric keys, enter the new weight and then press the ENTER key to save the new
setting and return to the 2xx-DAC SETUP MENU. If the weight is to be negative, press the +/-
key to toggle the sign and then press the ENTER key. Allowable values are: -99999 to
999999.
Ex. If the low weight is to be -1000, then key-in 1 0 0 0 +/- ENTER keys.
12
MODEL 225
2xx-DAC SETUP MENU
GROSS ONLY=NO
DAC output is the displayed Weight
(gross or net)
2xx-DAC SETUP MENU
8200-M350-O1 Rev B • 2XX-DAC
NO
The display will change to show the