Download Print this page

Cardinal 205-DAC Installation Manual page 10

Digital to analog converter

Advertisement

P1
CAUTION! If the main board assembly doesn't go completely into the
enclosure, DO NOT attempt to force it in. Gently lift the rear edge of the main
board assembly, and then continue to slide it into the enclosure until the rear
panel is against the back edge of the enclosure.
External Cable Installation
1. The wires from the external ANALOG OUTPUT cable are connected to the P2 terminal
block on the rear panel of the indicator. Refer to Figure No. 8 for the location of P2.
2. Remove 2" of the outer insulation jacket then remove 1/4" of insulation from each wire.
3. Connect each of the wires to terminal block P2 referring to the labels on the rear panel and
the P2 detail view for terminal connections.
4. Loosen the screws in the terminal block, then slip the wire into the terminal opening and
tighten the screw to lock the wire in place. Repeat the procedure until all wires are in place.
Figure No. 8
Securing the Rear Panel
After all adjustments have been made, replace the calibration access cover (if required) and
install the 4 screws removed earlier to secure the rear panel to the enclosure. If required,
install the lead and wire calibration seal.
6
INSTALLATION, CONT.
MODEL 200
ANALOG OUTPUT CABLE
P2
Figure No. 7
8200-M350-O1 Rev B • 2XX-DAC
LIFT GENTLY
P2 Detail View

Advertisement

loading

This manual is also suitable for: