1. APPLICATION
The NIPRESS D-300 series pressure transmitter measures pressure and converts it into voltage or current. It
can be used in 2- and 3-wire systems. The wide choice of the models makes it suitable for many pressure
measurement tasks whether relative or absolute pressure, static or dynamic measurement is required. Two
different accuracy classes are available.
The design of the transmitter, the wide temperature range and high overload capability and the possibility to
install the unit in any position, allows their application in many different industrial circumstances.
2. TECHNICAL DATA
T
YPE
Measurement range
Overload capability
Accuracy
Medium temperature
Ambient temperature
- 40 °C ... + 85 °C (- 40 °F ... + 185 °F) (with integral cable: -5 °C ... +70 °C [- 40 °F ... + 158 °F])
Sensor type
Materials
Sensor:
of the
Sensor sealing:
wetted
Process conn.:
parts
Housing
Output
4 – 20 mA output: U
Power supply
4 – 20 mA output, SIL version: U
Load resistance
R
Process connection
Electrical connection
Ingress protection
Shock-hazard protection
Mass
S
PECIAL DATA FOR EX CERTIFIED MODELS
T
YPE
Ex marking
Power supply
Intrinsically safe data
Permissible temperatures for
environment
Connecting cable (in case of the
device equipped with integral cable)
2.1 A
CCESSORIES
User's manual
Warranty Card
EU Declaration of Conformity
2.2 O
RDER CODE (N
OT ALL COMBINATIONS POSSIBLE
M
P
EASURING
C
ODE
METHOD
CONNECTION
Relative
R
¼" BSP
Absolute
E
½" BSP
(1)
¼" NPT
½" NPT
M20 x 1.5
(1) Only above 0.4 bar
(2) Up to max 40 bar
(3) Only without SIL
(4) P
< 0.4 bar
N
D – 3 – 2
D – 3 – 6
D – 3 – C
D – 3 – D
-1 – 600 bar (according to the order code)
According to the order code
P
≥ 0.4 bar: ±0.25%, P
< 0.4 bar: ±0.5%, Optional: ±0.1%
N
N
- 40 °C ... + 125 °C (- 40 °F ... + 257 °F)
Piezoresistive
1. 4435 stainless steel (internal membrane)
FKM (Viton), EPDM (P
1.4404 (316L) stainless steel
1.4404 (316L) stainless steel
4 – 20 mA
= 8 – 32 V DC
Supply
= 14 – 28 V DC
Supply
4 – 20 mA 2-wire current output:
= (U
– U
) / 0.02 A [Ω]
max
Supply
Supplymin
According to the order code
ISO 4400, M12x1 / 4, integral cable
IP65 (ISO 4400) / IP67 (M12x1) / IP68 (integral cable)
SELV Class III
~ 0.2 kg (~ 0.44 lb)
(
4 – 20 mA / 2-
ONLY FOR
The supply connections have an inner capacity of max. 27nF to the housing.
!)
NIPRESS
D
– 3
R
ANGE
ROCESS
C
ODE
A
- 1
C
0
G
0
(2)
H
0
J
0
0
0
0
0
0
0
D – 3 – 3
 160 bar)
N
0 – 10 V
0 – 10 V DC output: U
= 14 – 30 V DC
Supply
0 – 10 V DC voltage output: R
> 10 kΩ
min
)
WIRE
D – 3 – 6 Ex
D – 3 – D Ex
(Pending)
U
= 10 V ... 28 V DC
supply
Use only with Ex ia certified power supply!
U
= 28 V DC, I
= 93 mA, P
= 660 mW, C
imax
imax
imax
Zóna 1, 2:
–20 °C ... +70 °C
Zóna 0:
0,8 bar ≤ P
≤ 1.1 bar : –20 °C ... +60 °C
ATM
Cable capacitance: 160 pF/m
Cable inductivity: 1 µH/m
/ (
R
OVERLOAD
)
C
CAPABILITY
ODE
BAR
0
(5)
0
0
0.1
(0.5)
1
0
0.16
(1)
R
0
0.25
(1)
2
0
0.4
(2)
3
0
0.6
(5)
4
0
1
(5)
5
0
1.6
(10)
6
0
2.5
(10)
7
0
4
(20)
8
0
6
(40)
9
≈ 0 nF, L
≈ 0 µH
i
i
/ (
ANGE
OVERLOAD
)
C
O
CAPABILITY
ODE
UTPUT
BAR
10
(40)
A
4 – 20 mA 2-wire
16
(80)
B
0 – 10 V 3- wire
25
(80)
C
4 – 20 mA 2- wire / Ex ia
40
(105)
D
4 – 20 mA 2- wire, SIL2
60
(105)
E
4 – 20 mA 2- wire, SIL2 / Ex ia
100
(210)
F
160
(600)
G
250
(1000)
H
A
CCURACY
400
(1000)
J
0.25 %
600
(1000)
K
0.5 %
0.1 %
IBExU: pending ● drc3612a0600h_05 ● 1/3
/ E
C
X
ODE
2
3
6
C
D
C
ODE
1
(1)
2
(4)
4
(3)

Advertisement

loading

Summary of Contents for NIVELCO NIPRESS D-300 Series

  • Page 1 We are sure that you will be satisfied throughout its use! 1. APPLICATION The NIPRESS D-300 series pressure transmitter measures pressure and converts it into voltage or current. It can be used in 2- and 3-wire systems. The wide choice of the models makes it suitable for many pressure measurement tasks whether relative or absolute pressure, static or dynamic measurement is required.
  • Page 2 2.3 D Mounting steps for NPT thread connections: IMENSIONS Use a suitable sealant (e.g. PTFE tape). Turn the device by hand to the correct DC―3― thread and tighten it with an open-end torque wrench. 4. WIRING Shielded and twisted multicore cable is recommended for the electrical connection.
  • Page 3 7. MAINTENANCE AND REPAIR The instrument does not require regular maintenance. Repair will be carried out at the NIVELCO' premises only. When dismantling the device, it must always be done in depressurized and currentless condition! Check also if the medium has to be drained off before dismantling.