1 General information.
1.1
Introduction
The PD 340 Flow Transmitter is a precision meter for the volumetric measurement of liq-
uids that are electrically conducting.
The rugged construction of the transmitter makes it suitable for installations where solid par-
ticulates make up part of the liquid for measurement.
This manual is applies to PD 340 Flow Transmitters that utilise the 'Version 2' electronics
module.
1.2
Features
•
Sanitary design
•
Maintenance-free, no moving parts
•
Automatic zero point correction
•
High accuracy, even at very low flow rates
•
Bi-directional flow
•
Volumetric measurement in m
•
Pulse output to an electronic counter, 0-1000 pulses per second
•
Pulse output to an electromechanical counter, 0-10 pulses per second
•
Current output, 4-20 mA (extended version)
•
Batch control function
•
Limit switch function
•
Flow regulator function (PI controller)
•
Practically no loss of pressure
•
A PD 210 display unit can be simply connected. The PD 210 unit can display accumu-
lated volume, setpoint for batch control or PI regulator, flow rate, temperature, etc.
•
Count stop/clear logic input function.
•
Temperature measurement using an external temperature sensor
•
Temperature compensated flow measurement
•
Continuous Selftest, which can be monitored through P-NET
•
P-NET Fieldbus Communication (IEC 61158 Type 4)
•
EMC approved (DS/EN 61000-6-2) (DS/EN 61000-6-3)
•
Vibration approved (IEC 60068-2-6 Test Fc)
Manual
3
, litres, U.S. gallons etc.
Flow Transmitter, PD 340
502 010 05
5/55