Standard Settings - Proces-Data PD 340 Manual

Flow transmitter
Hide thumbs Also See for PD 340:
Table of Contents

Advertisement

The P-NET node address is a two-digit number in the range from 01 to 7D in hexadecimal
readout, where digit 5 is the most significant digit. When using the PD 210 display unit, only
the digits from 0 to 9 can be used, and thus the highest possible node address is 79.
See also the
Batch control application example
register.
6.2

Standard settings

If specific functions are not requested at time of order, the transmitter will be delivered with
the following standard settings:
Variable name
PD 210 address
MeterSize
E1
Scale
Standard
E5
Extended
Code1
E6
Code2
Standard
E7
Extended
Code3
E8
Note:
Only digits 1 to 6 are applicable to the PD 210 display unit.
These standard settings result in the following output configurations:
Standard version :
Output2:
Output3:
Extended version :
Output2:
Output3:
Manual
C 25
C 38
8.0
20.0
.000010
.000010
8.00000
20.0000
33333300
33333300
41110000
41110000
21110000
21110000
30241100
30241100
1 litre/pulse (C 25 and C 38)
10 litre/pulse (C 51, C 63 and C 76)
0.01 litre/pulse (C 25 and C 38)
0.1 litre/pulse (C51, C63 and C 76)
1 litre/pulse (C 25 and C 38)
10 litre/pulse (C 51, C 63 and C 76)
20 mA at max flow rate
Flow Transmitter, PD 340
for a specific configuration of the Code3
C 51
C 63
40.0
80.0
.000100
.000100
80.0000
40.0000
22222200
22222200
41110000
41110000
21110000
21110000
30241100
30241100
502 010 05
C 76
120.0
.000100
120.000
22222200
41110000
21110000
30241100
37/55