Viessmann Vitodens 200 Operating Instructions And User's Information Manual page 16

Wall-mounted, gas-fired condensing boiler
Hide thumbs Also See for Vitodens 200:
Table of Contents

Advertisement

Operation
Changing the Activation Periods
16
(continued)
Setting individual activation periods for individual days of
the week
To set the required day of the week
1. Press the "1-7" button and turn the "G" selector
knob clockwise or counter-clockwise until the arrow
"|." points to the day of the week (1 = Monday,
2 = Tuesday etc ) for which you wish to set the
switch-on and switch-off times.
2. Release the "1-7" button
To change the switch-on time for the first activation period
1. Press the red "
turn the "G" selector knob clockwise or counter-
clockwise until the required switch-on time appears.
2. Release the red "
time is stored.
To change the switch-off time for the first activation period
1. Press the blue "\" button under the symbol "r"
and turn the "G" selector knob clockwise or
counter-clockwise until the required switch-off time
appears.
2. Release the blue "\" button. The displayed switch-
off time is stored.
To select other activation periods (two to four)
1. Press the red "
under the symbol "r" simultaneously.
The figure "
Note: the figure "1" stands for the first activation period.
2. Within five seconds, turn the "G" selector knob
clockwise until the required activation period "2", "3"
or "
" appears along with the corresponding number
4
of horizontal bars.
3. To set the switch-on and switch-off times, follow the
same procedure as for setting the first activation
period.
Note: Approx. three minutes after you have finished
the setting the arrow "|" automatically jumps
to the current day of the week.
For the heating circuit with mixing valve
Change the activation periods accordingly on timer
channel "M".
For the domestic hot water supply
Change the activation periods accordingly on timer
channel "w".
For the DHW circulation pump
Change the activation periods accordingly on timer
channel "p".
Vitodens 200, WB2 Operating
" button under the symbol "r" and
0
" button. The displayed switch-on
0
" button and the blue "\" button
0
" appears for five seconds.