Copyright 2003© Siemens AG

3 Connector IO Jack

Fault Symptoms
Customer:
Charging Problems
Problems with external loudspeaker or microphone when using a car kit
Problems with accessories connected at the IO connector
Exchange
IO connector
Connector IO Jack
Use soldering iron to remove defective component. Avoid excessive heat! Watch surrounding components!
Resolder new component afterwards.
E-commerce order number:
Soldering temperature:
IRIS Diagnose Code:
Service Repair Documentation
Level 2.5 - C65
IO connector Problems
Watch for oxidation and
damaged pads of the
IO connector
Check for dust inside
the IO connector
not okay
Check the status of the
IO connector visually
Use the resistor test
function of a multimeter
to check connection
not okay
between spring
contacts and soldering
contacts. The value
must be ~0Ω
L36334-Z93-C303
240 - 255°C
46100 Interface/Charging Connector/Mechanical Damage
47300 Interface/Data Interface/Mechanical Damage
4B100 Interface/Headset Connector/Mechanical Damage
Page
GRT:
No connection to GRT
Tbd.
not okay
okay
not okay
okay
okay
okay
of
6
13
SCRAP
don´t
WSC
send back to
Clean
IO connector
- check for twisted or
bended contacts
- check for dry joints
Level 2 Repair
Release 1.0