Filling of the nitrogen cylinder

4.1 Filling the nitrogen cylinder
16
Charging tubing may be put under pressure.
During the end coupling of the charging tubing via the quick coupling,
ensure that the coupling is fixed by hand. The pressure at the end
coupling immediately escapes with a loud bang.
When filling the nitrogen cylinder with nitrogen, the pistons can extend
suddenly.
During the filling process, slowly increase the pressure in order to
prevent sudden extension.
Maintain a sufficient distance and do not reach into the piston's
movement space.
Only use nitrogen N
2
specifications (
OI, 4.2 Nitrogen filling pressure table) With nitrogen
cylinders with a higher filling pressure, use appropriate nitrogen bottles
(Manufacturer's recommendation: 300 bar nitrogen bottles).
1. Chuck the base body into a vice.
2. Connect the charging tubing to the nitrogen bottle pressure reducer.
3. Connect the charging tubing to the quick-fit connector on the base body. First
close the control set regulating valve, and then the outlet valve.