USRIC-4 Factory Presets
®
LogTag
USRIC-4 recorders can be client configured using LogTag
configured with a factory profile, ready for starting.
If a default configuration does not suit, customers can compile their own profile by specifying the parameters in the tables below when ordering.
Please note that minimum order quantities apply for USRIC-4 recorders with profiles not stocked by LogTag
Description
Standard Options
UserID
Start method
Record pre-start readings
Number of readings to record
Sampling interval
Start Delay
Enable Green OK indicator
Reset alarm with
START
/Mark
Alarm remains active when readings return to spec
Configure requires password
Download requires password
Password
Standard Alarm Parameters
Alarm direction
Trigger this alarm
Upper Alarm
Temperature threshold value
Alarm activation type
Activation delay time
Alarm direction
Trigger this alarm
Lower Alarm
Temperature threshold value
Alarm activation type
Activation delay time
For rules regarding setting up multiple alarms please see
1
All units associated with a profile must have the same UserID. The text cannot be individually customised per unit. The text cannot contain characters from an extended character set
such as Chinese or Cyrillic
2
Upper value must be above lower value
3
Instant = one temperature reading is above (below) the threshold
l
Consecutive = temperature readings are above (below) the threshold for the time defined in the activation delay without interruption
l
Accumulative = temperature readings are above (below) the threshold for the total time defined in the activation delay time, but may not necessarily be sequential.
l
Page 8 of 9
Default Profile
-
Push button start
enabled
3,900
5 minutes
60 minutes
enabled
disabled
button
enabled
disabled
disabled
-
upper
disabled
2
-
3
instant
-
Lower
disabled
-
instant
-
Alarm Configuration Options
®
Analyzer. For an out-of-box solution they can also be ordered in volume, pre-
Range/Option
ASCII text up to 38 characters
Push button start
enabled or disabled
1-3,937
1 minute to 18 hours
1 minute to 72 hours, 0=no delay
enabled or disabled
enabled or disabled
enabled or disabled
enabled or disabled
enabled or disabled
Up to 6 ASCII characters
upper
enabled or disabled
-25°C to 60°C (-13°F to 140°F)
instant, accumulative or consecutive
1 minute to 45 days
Lower
enabled or disabled
-25°C to 60°C (-13°F to 140°F)
instant, accumulative or consecutive
1 minute to 45 days
on page 1.