2. Keeping the Storage personality module vertically straight position, insert the guiding slot (inner/outer) into the
chassis wall-support and gently press down the module down until it seats firmly in its slots. Refer
SPM side facing chassis sidewall
Figure 82 Guiding slots present on the inner and outer side of a Storage personality module
3. Rotate and press the swing-arms inwards to lock the Storage personality module (See
Figure 83 Locking the SPM at its place using swing-arms
4. Insert Controller module back into the chassis and the Storage personality module, and do the required connections.
5. Verify that the Storage personality module fault LED is OFF. Verify that the front panel LED states show no amber
module faults.
6. If replacing both Storage personality modules, repeat above procedure.
Reattach top lid "B" after you complete the procedure.
SPM side facing drives
Figure
83).
Replacing a Storage personality module
Figure
82.