INSTALLATION MANUAL
¹ This installation manual contains instructions valid for all
configurations of the ICY device
WARNING:
Safety is guaranteed if these instructions are followed and
therefore they must be kept. Installation may require the
involvement of qualified personnel. Before proceeding with
installation of the device ensure that the environmental
conditions are in compliance with and suitable for the
product characteristics. Before any operation on the device
disconnect mains power.
CONFIGURATION:
Instructions for installation and use contained in this manual
are valid for several configurations of the ICY device, for
which there are differences. The ICY TD (Touch-Dimmer)
model refers to the configuration of the device that includes a
dimmable electronic switch. The ICY IFR (PIR Sensor) model
refers to the configuration of the device that includes an
electronic presence-detecting sensor.
The ICY TW (Tunable White) models refer to the
configurations of the devices that have a built-in LED source
with dynamic light colour adjustment. for correct operation
of the ICY TW devices they must be connected exclusively to
an adjustment system supplied by DOMUS Line such as
MAGIC BOX, MAGIC TUNE, TOUCH TW, etc., sold separately.
For more detailed information on DOMUS Line Tunable White
adjustment system characteristics and models go to
www.domusline.com or contact us.
EN
The parts of the installation and use manual common to all
models relate to the ICY model, or the configuration of the
device that does not incorporate a switch or sensor.
INSTALLATION:
– The ICY is a lighting profile for installation in built-in recesses.
Recess measurements corresponding to the designs in figure 1
and figure 2 are indicative and may vary depending on the
application and the assembly plan material.
– The ICY can be installed using the lighting profile power cable
in axial (figure 1) or radial (figure 2) position with respect to
the assembly plan. For installation using the power cables in
axial position, a hole measuring ø ≥ 8mm must be drilled, as
shown in the example in figure 1. For installation using the
power cables in radial position, a hole measuring ø ≥ 8mm
must be drilled, as shown in the example in figure 2. In
terms of specific requirements, it is possible to drill the
power cable outlet hole in other positions, provided they
do not affect the integrity of the cable and/or connector
installed on it.
– Position the supporting springs (A) provided in the
package by applying light pressure to the aluminium profile
(B), as indicated in figure 3.
– Feed the power cable (C) into the hole and install the
lighting profile by applying light pressure until it is seated
in the recess, as shown in figure 4.
Need help?
Do you have a question about the ICY and is the answer not in the manual?