Download Print this page

Prima FIT II Installation Instruction page 8

Advertisement

IMPORTANT Please read these instructions prior to installation. Refer to the Prima catalog for proper lamp type and maximum wattage for xtures.
Prima is not responsible for any xture or system failure caused by unsupported lamps. Contact Prima customer service for the latest updates on
which lamps we support and proper usage. Prima low voltage transformers must be used with all Prima Lighting product installations. All warranties
are void if Prima transformers are not used. Prima's catalogs provide general information and suggestions for proper dimmer usage. Please consult
our customer service department with any questions regarding dimmer speci cs. Prima is not responsible for any damage caused by improper
dimmer speci cation and usage. Use only quali ed electrician for installation. Adhere to all local and national electrical codes prior to installation.
straight connector for horizontally or vertically oriented track
It is strongly recommended that gloves are used when handling the FIT II System track. Oils and dirt from ngers can sometimes permanently
mark the nish. Track should be cleaned with a damp cloth and thoroughly dried before xture installation.Connectors are available for
extending track length, turning corners or creating intersections in the run. Great care must be taken to ensure the connector is installed
properly.
The Straight Inline connector for horizontal or vertical orientations has the bene t of being virtually undetectable after installation. This
I
connector does not add any length to the over all track run. Insert the conductive (22-79132) or non-conductive (22-79133) inserts into the
conductor hole on one of the track lengths. Insert the top and bottom cover half way into the same track length and secure by tightening the set
screws with a at head screwdriver. Connect the second track length and secure by again tightening the set screws with a at head screw driver.
There should be no space between the connected track lengths after installation is complete.
connectors for horizontally oriented track
FIT II system connectors are available in 2, 3 and 4 way versions. The example below demonstrates a three way connector for horizontally
J
that during the connector installation process, the track conductors were not pushed out the opposite side of the track length. T his is explained in
detail in Part 1 of this instruction manual. Be sure to tighten all of the lock screws on the connector.
Track connector for horizontally oriented track
connectors for vertically oriented track
K
FIT II system connectors are available in 2, 3 and 4 way versions. The example below demonstrates a three way connector for vertically
oriented track. It is especially important to ensure that all track lengths are rmly attached to the connector. It is also important to ensure
that during the connector installation process, the track conductors were not push out the opposite side of the track length. This is explained in detail
in Part 1 of this instruction manual. Be sure to tighten all of the lock screws on the connector.
Track connector for vertically oriented track
*Caution
*Caution:
Do not break the insulator inside
the chamber while using the
screw-in function. Broken insulator
will cause short of circuit. This a pplies to 2, 3, and 4 way connectors.
All track lengths are rmly attached
13615 Marquardt Ave. Santa Fe Springs, CA 90670
Ph. 562-407-3079 . Fx. 562-407-3069
www.primalighting.com
ortant to ensure
Tighten all of the lock screws
Tighten all of the lock screws