Theben Timeguard SupplyMaster FST24 Installation & Operating Instructions Manual page 10

Fused spur time switch
Table of Contents

Advertisement

• Either – Accept this by pressing the Prg button once, and review
the programmed times for this mode by pressing Prg to move
through the times
• Or – Press the Adv/Over or Boost button to change the mode,
and then press the Prg button to review the times.
Note: If you wish to change the mode at this stage, doing so will
result in programmes being lost and they will need to be re-entered.
• Review times and adjust as necessary as described at the start
of section 9.
10. Advance/Override button
In normal operating mode the Adv/Ovr button advances the programme
to the next time change.
• If the output is currently OFF, it will change the output
to ON ADVANCE, until the next programmed OFF time.
• If the output is currently ON, it will change the output
to OFF ADVANCE, until the next programmed ON time.
• A second push of the Adv/Ovr button selects a permanent
9
ON mode, ON OVERRIDE, where the output is ON irrespective
of the programming.
• A third push of the Adv/Ovr button selects a permanent OFF mode,
OFF OVERRIDE, where the output is OFF irrespective
of the programming.
• A fourth push of the Adv/Ovr button returns the unit to normal
operating mode, where the output will conform to the programming.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeguard supplymaster fst77