DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
The field current exceeds the current limit
-66
of the field transistor.
MEMORY RECALL
YES
SYMPTOM
Control will not operate or is sluggish on
Circuits valid
start up. Line contactor opens.
for
Traction
POSSIBLE CAUSES
Controller
•=Shorted field F1 to F2
•=F1 or F2 terminals shorted to battery
positive (B+) or to battery negative (B-)
•=Binding line contactor
•=Visually inspect tips, clean them with a
solvent.
•=Noise
•=Confirm that all inductive
loads/accessories are suppressed.
•=Excessive motor and control heating
(control is in thermal cutback)
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Capacitor (1C) voltage too high during
-76
pedal up regen braking.
MEMORY RECALL
YES
SYMPTOM
Line contactor opens and closes, then
Circuits valid
opens and can only close by opening
for
and closing the key switch.
Traction
Controller
POSSIBLE CAUSE
Defective control.
•=
Batteries are overcharged.
CORRECTIVE ACTIONS
CORRECTIVE ACTIONS
Replace controller unit.
CAUSE OF STATUS INDICATION
This status code will be displayed when the field
transistor exceeds its current limit. The line
contactor will drop out and the key switch will have
to be recycled to restart the control.
TROUBLE-SHOOTING DIAGRAM
CHARGER
KEY
SWITCH *
SWITCH
DIRECTIONAL
*
SWITCH *
P1
P2
P3
P15 P14 P16
CAUSE OF STATUS INDICATION
This status code will be displayed when the voltage at
1C exceeds 96 volts during the regenerative braking
cycle.
TROUBLE-SHOOTING DIAGRAM
FU3 *
10A
LINE *
FU1 *
400A
+
POS
POWER CONNECTIONS
-
NEG
Page 27
*
L
P4
P5
P11 P10
PLUG (23 PIN)
P7
P9
P8
P13
P6
P21
F1
A1
A1
F1
TO CONTROL
F2
A2
A2
F2
July 2002
A1
A2

Advertisement

loading