OPERATING THE
GENERATOR
CAUTION
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.
• See "Don't Overload Generator".
• Start generator and let engine stabilize before connecting
electrical loads.
• Connect electrical loads in OFF position, then turn ON for
operation.
• Turn electrical loads OFF and disconnect from generator
before stopping generator.
Starting the Engine
Disconnect all electrical loads from the generator. Use the
following start instructions:
1.
Make sure unit is on a level surface.
IMPORTANT: Failure to start and operate unit on a level
surface will cause the unit not to start or shut down during
operation.
2.
Turn the fuel valve to the "Open" position (fully
clockwise) (Figure 5).
Figure 5 — Fuel Valve in Open Position
3.
Slide the choke lever to the "Choke" position (all the
way to the right) (Figure 6).
Figure 6 — Choke Lever
2000W Generator
4.
Place the engine switch in the "On" position (Figure 7).
Figure 7 — Engine Switch in On Position
5.
Grasp starter grip and slowly pull the rope until you
feel some resistance, then pull the cord out with a
rapid full arm stroke. Let rope return slowly. DO NOT
let rope "snap back" against the unit.
• When starting engine, pull cord slowly until resistance is felt
and then pull rapidly to avoid kickback.
• NEVER start or stop engine with electrical devices plugged in
and turned on.
NOTE: If engine starts after 3 pulls, but fails to run for
more than 10 seconds, check for proper oil level in
crankcase. This unit is equipped with a Oil Alert System
(see page 10).
• DO NOT touch hot surfaces.
• Allow equipment to cool before touching.
• The generator must be at least 5 feet from structures having
combustible walls and/or other combustible materials.
• Keep at least 3 feet of clearance on all sides of generator for
adequate cooling, maintenance and servicing.
• In the State of California a spark arrester is required by law
(Section 4442 of the California Public Resources Code).
Other states may have similar laws. Federal laws apply on
federal lands. If you equip the muffler with a spark arrester, it
must be maintained in effective working order.
9
WARNING
Rapid retraction of starter cord (kickback) will
pull hand and arm toward engine faster than
you can let go.
Broken bones, fractures, bruises or sprains
could result.
WARNING
Running engines produce heat. Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Combustible debris, such as leaves, grass, brush,
ect. can catch fire.