Download Print this page

Honda WDP30X Instructions Manual page 50

Hide thumbs Also See for WDP30X:

Advertisement

WDP30X
c. INSPECTION
• VALVE SPRING FREE LENGTH
Measure the free length of the valve springs.
Standard
Service limit
30.5 mm (1.20 in)
29.5 mm (1.16 in)
Replace the springs if they are shorter than the service limit.
• VALVE SEAT WIDTH
Measure the valve seat width.
Standard
Service limit
0.8 mm (0.03 in)
2.0 mm (0.08 in)
If the valve seat width is under the standard, or over the
service limit, recondition the valve seat
(P.
8-6).
• CYLINDER HEAD
STRAIGHTEDGE
FEELER GAUGE
Remove carbon deposits from the combustion chamber.
Clear any gasket material from the cylinder head surface.
Check the spark plug hole and valve areas for cracks. Check
the cylinder head for warpage with a straightedge and a
feeler gauge.
Service limit
0.10 mm (0.004 in)
8-3
Date of Issue: April 2008

Advertisement

loading

This manual is also suitable for:

Wdp30xk1Wdp30xk2