24. Reset some parameters in the system.
Press the settings icon in the main menu to select the reset menu and select the parameters you want to
reset.
25. Setting up the entrance station.
Press the "settings" icon in the main menu, select "device configuration ",then "List of input stations ", and
select the desired input station , go to "Edit ", enter
correct password (default password is "0") and confirm with the "#" icon. Here you can set all
theparameters of the
station.
entrance

26. Device number.

The device number is 8 digits, you can set any one. If there is more than 1 entry station in the system,
you must not use the same device number for 2 input stations.

27. Button address.

By default, the address is button 1, and the default address of the monitor room is also 1.
After installation, you can call the internal monitor. If you have changed the "room address" on the

monitor,

you must also set a call target for the input station buttons.
Settings: Select the button 1 address menu in your input station settings and set the room address of the
monitor you want to call. After setting up, you can press the button at the entrance station to call monitors
with the room address set.
Note: If the button address is not set in the same way as the address of the target
monitor, the monitor can monitor the input station, but the input station cannot call the monitor.

28. Private equipment.

If this feature is enabled, the input station can be set up as a private device for only one family. A private
entry station can only be monitored by this family and can only be called to this family.
29. Monitor (monitor).
If this feature is enabled, the input station can be monitored by internal monitors.
If you disable this feature, the monitors will not monitor the input station.
30. Unlock with monitor.
If this feature is enabled, you can unlock the door or gateway in the tracking state by pressing the "Unlock"
icon. If you disable this feature, you can unlock the door or gateway only when you make a call by pressing
the unlock icon.
31. State of the door lock.
If you connect a door lock to the system, you must enable this function, set
"Unlock time " and by lock type "Unlock signal type" (Normally open or Normally closed).
32. The state of the gate lock.
If you connect a gateway lock to the system, you must enable this feature, set
"Unlock time " and by lock type "Unlock signal type"
(Normally open or Normally closed).
33. Type of outgoing button.
Set the target of the outbound button control on the door or gateway, depending on the actual
installation. Press the exit button to open the door/gate lock.