Beko BEVPI 090 Installation Manual page 47

Split-type room air conditioner
Hide thumbs Also See for BEVPI 090:
Table of Contents

Advertisement

Available languages

Available languages

8
Air evacuation
Connective pipe
Air purging
length (m)
method
≤ Standard pipe
Vacuum
length
Pump
> Standard pipe
Vacuum
length
Pump
Warning
A
DO NOT mix refrigerant types.
Split-type room air conditioner / Installation Manual
Additional refrigerant per pipe length
Liquid Side: Ø 6.35 (ø 0.25")
R22:
(Pipe length – standard length) x 30g/m
(Pipe length – standard length) x 0.32oZ/ft
Inverter R410A:
(Pipe length – standard length) x 15g/m
(Pipe length – standard length) x 0.16oZ/ft
Fixed-frequency R410A:
(Pipe length – standard length) x 20g/m
(Pipe length – standard length) x 0.21oZ/ft
Additional refrigerant
N/A
Liquid Side: Ø 9.52 (ø 0.375")
(Pipe length – standard length) x 60g/m
(Pipe length – standard length) x 0.64oZ/ft
Inverter R410A:
(Pipe length – standard length) x 30g/m
(Pipe length – standard length) x 0.32oZ/ft
Fixed-frequency R410A:
(Pipe length – standard length) x 40g/m
(Pipe length – standard length) x 0.42oZ/ft
R22:
47 / 120 EN