Download Print this page

Ambirad TORNADO Installation And Operating Manual

Gas fired mobile heater
Hide thumbs Also See for TORNADO:

Advertisement

Quick Links

Instruction Manual.
I
NSTALLATION AND
INDEX
Introduction ---------------------------------------------------------------------- 1
Installation Requirements ---------------------------------------------------- 2
Technical Details ---------------------------------------------------------------- 3
Operating Information --------------------------------------------------------- 4
Cleaning & Maintenance ----------------------------------------------------- 5
Ducted Options ----------------------------------------------------------------- 6
Servicing Instructions ---------------------------------------------------------- 7
Fault Finding & Spare Parts ------------------------------------------------- 8
User & Operating Instructions ----------------------------------------------- 9
WARNINGS
1 This appliance must only be installed by a competent person in accordance with
the requirements of the Codes of Practice or the rules in force.
2 All external wiring MUST comply with the current IEE wiring regulations.
3 Warning this appliance must be earthed.
T
ORNADO
G
F
M
AS
IRED
O
H
OBILE
EATER
PERATING
M
ANUAL
INDEX
Section

Advertisement

loading
Need help?

Need help?

Do you have a question about the TORNADO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ambirad TORNADO

  • Page 1: Table Of Contents

    Instruction Manual. ORNADO IRED OBILE EATER NSTALLATION AND PERATING ANUAL INDEX INDEX Section Introduction ---------------------------------------------------------------------- 1 Installation Requirements ---------------------------------------------------- 2 Technical Details ---------------------------------------------------------------- 3 Operating Information --------------------------------------------------------- 4 Cleaning & Maintenance ----------------------------------------------------- 5 Ducted Options ----------------------------------------------------------------- 6 Servicing Instructions ---------------------------------------------------------- 7 Fault Finding &...
  • Page 2: Introduction

    Introduction. Welcome to the Ambi-Rad Tornado heater. A The information contained within this instruction revolution in mobile gas fired space heating. sheet is for use with Ambi-Rad products within the country of use and in accordance with the rules in...
  • Page 3: Technical Details

    Installation Requirements. Gas cylinders are heavy, never attempt to lift a 2.1 Gas leaks cylinder, full or empty, by yourself. Always get help. Propane gas is highly flammable and heavier than air. Consequently in the event of a gas leak there Keep cylinders upright at all times during use, is a risk of explosion.
  • Page 4 3.3 Internal Wiring Diagram...
  • Page 5 Operating Instructions. Plug the supply lead into the connector on the rear 4.1 Moving the product of the product. 4.1.1 Wheeling. Select the appropriate voltage. 4.1.2 Standing for storage. Uncoil the hose from around the rear ring. 4.2 Operating instructions Ensure that you have read all other detail included in these instructions prior to following the operating instructions detailed below.
  • Page 6: Cleaning & Maintenance

    Note When positioning the heater please ensure combustion fan does not operate, then check to that all inlets and outlets are unrestricted there are see if the overheat stat reset has tripped. This is no combustible materials in the vicinity. Please located behind the combustion fan access door - ensure the heated air is not directed towards the see 7.3)
  • Page 7: Ducted Options

    Ducted Options. 6.1 Ducted flue gasses 6.2 Ducted air The products of combustion can be taken away from the room where the product is being used by the use of a flue duct. To keep touch and floor temperatures to an acceptable level, Ambi-Rad recommend a twin wall flue pipe with a 108mm diameter capable of withstanding 175°C.
  • Page 8: Servicing Instructions

    Servicing Instructions. 7.1 Health and Safety IMPORTANT This heater should be serviced annually. These instructions are intended to be used only by competent service engineers, and details all the service operations that are authorised by the manufacturer. Isolate gas and electrical supplies before carrying out any repair work.
  • Page 9 7.6 Burner Maintenance Check that the fan spins freely without any sign of being out of balance or bearing noise. If so replace the fan. If fan operation appears fine, then with a soft brush remove dust from the impellers and motor. Replace after checking...
  • Page 10 The combustion chamber can now be unscrewed. Access to the injector is by removal of the screws that attach the orifice fixing plate to the burner as- sembly. Slide the burner assembly away from the firing tube to reveal the burner assembly. Inspect the burner electrode assembly condition To remove the injector with the burner head taking care when reassembling to ensure that the...
  • Page 11 To replace the electronic sequence controller, transformer, thermostat and pressure switch. Remove the fan access cover. Access to these components is via the hinged lid. Remove the lid securing screws. The thermal cut out is located on the inside back wall and can be changed by removing the two self tapping screws.
  • Page 12: Fault Finding & Spare Parts

    Fault Finding & Spare Parts. 8.1 Fault Finding Flow Chart Ensure gas & electricity supplies are enabled. Check: Does the power 1. Operation of any thermostat ON neon 2. Any external fuses illuminate? 3. Correct voltage is selected Does the Check: lockout neon 1.
  • Page 13 8.2 Spare Parts Item Description Part No. Item Description Part No. Ignition 2015S Transformer 200423 Controller Valve Mini - Harness Twin sol reg 2055 E300002 220/240 Low Gas Ignition & Pressure Switch 201307 Rectification 900050 (set to 20mbar) Leads (pair) Amber Neon Pepperpot Head 200988...
  • Page 14 8.2 Spare Parts cont. Item Description Part No. Item Description Part No. Handle Assembly Thermal Cut Out 900001 200544 Black Combustion Fan 200421 Wheel 200535 Axial Fan c/w 200433 Wheel Spacer 200354 Basket Axial Fan 1” push on fix 900049 200349 Capacitor with dome cap...
  • Page 15 Notes.
  • Page 16: User & Operating Instructions

    Brierley Hill West Midlands DY5 1QA United Kingdom. Telephone 01384 489700 Facsimile 01384 489707 Email info@ambirad.co.uk Website www.ambirad.co.uk AmbiRad is a registered trademark of AmbiRad Limited. Because of continuous product Technical Suport www.s-i-d.co.uk innovation, AmbiRad reserve the right to change product specification without due notice...