Installation
5. Remove enclosure access cover
Remove the enclosure access cover screws with the 4mm Allen
wrench to prepare the VersiCharge Ultra 175 for wiring
installation.
The enclosure access cover has an attached gasket. Ensure this
is carefully stored to avoid damage or accumulation of debris.
6. Remove tape and attach cable glands
Remove the tape from the field wiring input holes, and fit the
supplied 4x M32 cable glands and 1x M25 cable gland.
7. Prepare wiring
Fit the individual power cabling into each M32 cable gland,
ensuring there is enough length to add the M10 lugs (not
supplied) and attach to the busbars. Fit each wire with an M10
lug.
8. Remove M10 fasteners
Each installation busbar is fitted with M10 fasteners. Remove
these ready for wiring.
Installation Manual
CAUTION
To continue to achieve the NEMA 3R rating the power
cabling must be fitted correctly into the cable gland.
Ensure the cable is sitting correctly in the gland and tighten
to ensure no water or debris can enter. If in doubt, use an
appropriate outdoor rated sealant.
When the cable gland has been tightened, pull on the cable
to ensure it doesn't slip.