Settings

7 Settings
All the settings should be configured on the detector base before the detector is installed
permanently. The related function modules are shown as below.

Figure 7-1 Function modules on Detector Base

Tamper Switch

DIP Switch Settings

* Factory default settings are shown in grey.
- 18 -
DIP Switches
EOL Jumpers
ON
OFF
Sensitivity Settings
1
2
G
OFF OFF High sensitivity setting
high
Normal sensitivity
G
ON
OFF
normal
setting
G
OFF ON
Low sensitivity setting
low
Noisy environment
G
ON
ON
noisy
sensitivity setting
Any change of DIP switch 3 will cause an alarm.
Any change of DIP switch 3 must be followed by a power-off sequence of 5 seconds.
The Noise LED will light or flash intensively if the noise level (external or internal) is too
high. Reduce the sensitivity with DIP switch 1 and 2 until the Noise LED turns off.
Note
When scratching the surface of the protected object lightly, the Noise LED will turn on as a
confirmation of detection.
In case of alarm, the Noise LED will flash with 5 Hz, appx. 2.5 seconds.
Turning off the Noise LED by DIP switch 4 will reduce current consumption.
J1
Noise LED
J19
J20
Terminal Block
Application Settings
3
4
ATMs/ Night
OFF
OFF
deposit safes
ON
Safes / Vaults
ON
Noise LED
Noise indicator
OFF
Noise indicator
ON