Pressure Switch - Procopi RTM Premium 610-A Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

The max operating pressure is measured by an electronic pressure switch. The tripping pressure is set using the S4
switch. To alter the tripping pressure, use a screw driver to turn the arrow forwards or backwards until it points to the
desired value. (see the table below)
S4
Use a 15 mm socket wrench to remove the electric actuator from the valve.
Reverse the procedure to replace the actuator (8 to 1).
Mounting and tightening the turbidity sight glass (2) and the hex head screw (4) with a hand wrench (tightening torque
between 4 Nm and 8 Nm)

PreSSure SWitch

1
2
5
Pressure switch " bar "
0 = 0.5
4 = 0.9
1 = 0.6
5 = 1.0
2 = 0.7
6 = 1.1
3 = 0.8
7 = 1.2
DiSmantling
3
6
7
22/36
2010/03 - Indice de révision : A - Code : 0026700
8 = 1.3
C = 2.0
9 = 1.4
D = 2.5
A = 1.5
E = 3.0
B = 1.75
F = 3.5
4
8
1
Filtration