Programming the length of the back wash cycle
The length of the back wash cycle is set using the Switch S1.
There are 4 back wash cycle times to choose from.
S1
45 sec.
Programming the length of the rinsing cycle.
The length of the rinsing cycle is determined by the position of the S2 switch. There are 4 cycle times to
choose from.
S2
20 sec.
Setting the frequency of the back wash cycles.
Use the switch, S3, to set the back wash cycle interval.
There are 4 intervals to choose from.
S3
Off
CAUTION! Before modifying the switch positions, move the valve to the "FILTRATION" position
(see page 16) and cut the power supply.
Back wash cycle interval.
Example: Back wash every Monday at 9:15 am.
- Put the switch S3 in the '7 day' configuration and energise the valve at 9:15 am on a Monday.
(Press the "ON" key).
To modify this setting, press "TEST BUTTON" on the day and at the time desired.
Example: Changing the switching point from Monday 09:15 to Friday 08:00.
- Press the " TEST BUTTON " key at 08:00 on a Friday.
75 sec.
120 sec.
40 sec.
60 sec.
3 days.
7 days.
21/36
360 sec.
90 sec.
14 days.
2010/03 - Indice de révision : A - Code : 0026700