Start position "filtrAtiON" - Device activated.
- Launch the back wash cycle by pressing " TEST BUTTON ".
- The "TEST BUTTON" indicator lamp lights up indicating that a back wash is underway.
- The output terminal " 13 - 14 " opens no flow).
- The ball valve output switches from terminal " 21 - 20 " to " 21 - 22 ".
the valve moves to the back wash position.
- The pump time-out counts down (approx. 10 seconds).
- The pump terminal output " 13 - 14 " closes.
- The pre-set back wash time counts down (Contact S1).
-
The pump terminal output " 13 - 14 " opens (no flow).
the valve moves to the rinsing position.
- The pump time-out counts down (approx. 10 seconds).
- The pump terminal output " 13 - 14 " closes.
- The pre-set rinsing time counts down (Contact S2).
-
The pump terminal output " 13 - 14 " opens (no flow).
the valve moves to the filtration position.
- The valve output switches from terminal " 21 - 22 " to " 21 - 20 ".
- The pump time-out counts down (approx. 10 seconds).
-
The pump terminal output " 13 - 14 " opens.
Switching and rinsing times:
- Time out
- SWITCHING from filtration to back wash
- Min / max back wash time
- SWITCHING from back wash to rinsing
- Min. / max rinsing time
- SWITCHING from rinsing to filtration
- Min. / max cycle time

cYcle Sequence

10 sec.
approx. 30 sec.
45 sec./ 360 sec.
approx. 22 sec.
20sec./ 90 sec.
approx. 18 sec.
approx. 2min. 34 sec./env. 9min.