Task Force Tips TRANSFORMER Instructions For Safe Operation And Maintenance

Task Force Tips TRANSFORMER Instructions For Safe Operation And Maintenance

Nozzle system

Advertisement

Quick Links

INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE
WARNING
WARNING
This instruction manual is intended to familiarize fi refi ghters and maintenance personnel with the operation, servicing and safety
procedures associated with the Transformer Nozzle System.
This manual should be kept available to all operating and maintenance personnel.
Nominal Rated Flow
150 GPM @ 100 PSI
(570 l/min @ 7 bar)
Maximum Operating Pressure
300 psi (20 bar)
TASK FORCE TIPS, INC.
MADE IN USA • www.tft.com
©Copyright Task Force Tips, Inc. 2013-2014
Understand manual before use. Operation of this device without understanding the manual and
receiving proper training is a misuse of this equipment. Obtain safety information at www.tft.
com/serial-number
This equipment is intended for use by trained personnel for fi refi ghting. Their use for other
purposes may involve hazards not addressed by this manual. Seek appropriate guidance and
training to reduce risk of injury.
TRANSFORMER
MANUAL:
PERSONAL RESPONSIBILITY CODE
The member companies of FEMSA that provide emergency response
equipment and services want responders to know and understand the
following:
1. Firefi ghting and Emergency Response are inherently dangerous activities
requiring proper training in their hazards and the use of extreme caution
at all times.
2. It is your responsibility to read and understand any user's instructions,
including purpose and limitations, provided with any piece of equipment
you may be called upon to use.
3. It is your responsibility to know that you have been properly trained in
Firefi ghting and /or Emergency Response and in the use, precautions, and
care of any equipment you may be called upon to use.
4. It is your responsibility to be in proper physical condition and to maintain
the personal skill level required to operate any equipment you may be
called upon to use.
5. It is your responsibility to know that your equipment is in operable
condition and has been maintained in accordance with the manufacturer's
instructions.
6. Failure to follow these guidelines may result in death, burns or other
severe injury.
FEMSA
3701 Innovation Way, Valparaiso, IN 46383-9327 USA
800-348-2686 • 219-462-6161 • Fax 219-464-7155
Nozzle system
Nozzle system
DANGER
Fire and Emergency Manufacturers and Service Association
P.O. Box 147, Lynnfi eld, MA 01940 • www.FEMSA.org
LIS-011 December 15, 2014 Rev02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TRANSFORMER and is the answer not in the manual?

Questions and answers

Summary of Contents for Task Force Tips TRANSFORMER

  • Page 1 This instruction manual is intended to familiarize fi refi ghters and maintenance personnel with the operation, servicing and safety procedures associated with the Transformer Nozzle System. This manual should be kept available to all operating and maintenance personnel.
  • Page 2 From the OFF position, a quarter turn to the left fully opens the waterway. To stop water fl ow from the ON position, turn the rotary shutoff valve a quarter turn to the right. Do not operate the Transformer Nozzle System with the rotary shutoff valve in the intermediate position between ON and OFF.
  • Page 3 NOTICE WRENCH TO ASSEMBLE THE TRANSFORMER NOZZLE SYSTEM. Use of the Transformer Nozzle System as a lever or a wedge may cause the unit to bend or NOTICE fracture. Such damage is considered abuse. The resulting damage is not covered under warranty.
  • Page 4 5.0 FOAM USAGE The Task Force Tips Transformer Nozzle System is suitable for use with Class A foam, especially when hidden hot spots need to be soaked. Generally, the reach with foam is approximately 10 % less than with water only. Actual results will vary based on brand of foam, hardness of water, temperature, etc.
  • Page 5 EL = Elevation loss in PSI The Transformer Nozzle System’s estimated device loss is between 30 and 40 PSI (2 to 3 Bar) for most confi gurations. For additional information on calculating specifi c hose layouts, consult an appropriate fi re-service training manual, A Firefi ghters Guide to Nozzles published by Task Force Tips, or call TFT’s “Hydraulics Hotline”...
  • Page 6 8.0 EXPLODED VIEW AND PARTS LIST PA206 PA227 PA226 PA228 ©Copyright Task Force Tips, Inc. 2013-2014 LIS-011 December 15, 2014 Rev02...
  • Page 7 WASHER VM4901 3/8-16 X 1 SOCKET HEAD SCREW VT37-16SH1.0 FLOW PATTERN EXTENSION SECTION PA120 PIERCING POINT PA141 NAME LABEL: TRANSFORMER PIERCING NOZZLE PA205 LABEL: ROTARY VALVE OFF - RED PA227 LABEL: ROTARY VALVE ON - BLUE PA226 FOLLOWER U251 3/8-24 X 3/8 DOG POINT...
  • Page 8 9.0 INSPECTION AND MAINTENANCE The Task Force Tips Transformer Nozzle System is designed and manufactured to be damage resistant and require minimal maintenance. However, as the primary fi refi ghting tool upon which your life depends, it should be treated accordingly.

This manual is also suitable for:

Pa1

Table of Contents