Codonics Virtua Manual

Codonics Virtua Manual

Medical disc publisher
Hide thumbs Also See for Virtua:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Table of Contents

EN - English .............................................................................................................................................................. 22
Documentation Notice ........................................................................................................................................ 22
Overview .............................................................................................................................................................. 22
Specifications ....................................................................................................................................................... 22
Product Information ............................................................................................................................................ 23
Warnings and Limitations of Use......................................................................................................................... 23
Location of Safety and Compliance Labels ...................................................................................................... 23
Voltage Warning .............................................................................................................................................. 24
Laser Warning .................................................................................................................................................. 25
Compliance ...................................................................................................................................................... 25
Serial Number, Configuration, Date Code, and Modification Codes ............................................................... 25
ESD Caution ..................................................................................................................................................... 26
Fuse Label ........................................................................................................................................................ 26
Potential for Radio Frequency Interference on Device Operation .................................................................. 26
Potential for Radio and Television Interference.............................................................................................. 26
Guidance Regarding Electromagnetic Emissions and Immunity ..................................................................... 27
Safety Precautions ........................................................................................................................................... 29
Location Precautions ....................................................................................................................................... 30
Cleaning Precautions ....................................................................................................................................... 30
Media Precautions ........................................................................................................................................... 31
Codonics Virtua Medical Image Viewer ........................................................................................................... 31
Medical and Patient Information .................................................................................................................... 32
Disposal Requirements .................................................................................................................................... 32
European Disposal Requirements ................................................................................................................... 32
Indications for Use ........................................................................................................................................... 32
Additional Warnings ........................................................................................................................................ 33

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtua and is the answer not in the manual?

Questions and answers

Summary of Contents for Codonics Virtua

  • Page 1: Table Of Contents

    Safety Precautions ............................29 Location Precautions ............................30 Cleaning Precautions ............................30 Media Precautions ............................31 Codonics Virtua Medical Image Viewer ......................31 Medical and Patient Information ........................32 Disposal Requirements ............................ 32 European Disposal Requirements ........................32 Indications for Use ............................32...
  • Page 2 DE - Deutsch ................................47 Dokumentation Beachten ........................... 47 Überblick................................47 Spezifikationen ..............................47 Produkt Information ............................48 Warnungen und Einschränkungen von Benutzen ....................48 Ort von Sicherheit und Beachtung Etiketten ....................48 Stromspannung Warnung ..........................49 Laser Warnung ..............................50 Beachtung ................................
  • Page 3 Ort Vorsichtsmaßnahmen ..........................55 Reinigung Vorsichtsmaßnahmen ........................56 Medien Vorsichtsmaßnahmen ........................56 Codonics Virtua Medizinisch Bild Zuschauer ....................57 Medizinisch und Geduldig Information ......................57 Verfügung Bedarf ............................57 europäisch Verfügung Bedarf .......................... 57 Indikationen zum Benutzen ..........................58 Zusätzlich Warnungen ............................. 58...
  • Page 4: En - English

    Virtua: Up to 30 CDs per hour, 15 DVDs per hour (based on a typical clinical study and network configuration) Virtua XR: Up to 62 CDs per hour, 31 DVDs per hour (based on a typical clinical study and network configuration) Processor: Intel®...
  • Page 5: Product Information

    For technical assistance with the Virtua, call Codonics Technical Support at the following number: Phone: +1.440.243.1198 Toll Free: 800.444.1198 (USA only) Technical Support is available anytime. Technical Support is also available online via email and the Codonics web site: Email: support@codonics.com Web Site: www.codonics.com...
  • Page 6: Voltage Warning

    WARNING To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth. WARNING Do not touch a patient while also accessing Virtua internal components that are under the front cover. EQUIPMENT IS NOT TO BE USED AS A COMPONENT OF A LIFE SUPPORT SYSTEM. Life support devices or...
  • Page 7: Laser Warning

    Laser Warning The Codonics Virtua Medical Disc Publisher contains a laser diode in the Recorder unit of a class higher than 1. To ensure continued safety, do not remove any covers or attempt to gain access to the inside of the product.
  • Page 8: Esd Caution

    ESD Caution Connections to other pieces of equipment are made at the rear of the Codonics Virtua Medical Disc Publisher. These connectors are marked with a precautionary ESD warning symbol, as shown below. Do not touch any of the pins of these connectors. When making connections to the device, it is best done while the device is plugged in but not powered on.
  • Page 9: Guidance Regarding Electromagnetic Emissions And Immunity

    WARNING Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the Virtua, its cables, or accessories. Otherwise, degradation of the performance of this equipment could result.
  • Page 10 Electromagnetic Immunity Standards and Test Levels:...
  • Page 11: Safety Precautions

    Safety Precautions Never connect this device to any outlet or power supply that has a voltage or frequency different than that specified and set on the rear of the device. When servicing the device, always power it off using the green soft power button on the Controller front panel, turn the hard power switches at the rear of the Controller and Recorder to the 0 (off) position, then unplug the device.
  • Page 12: Location Precautions

    If the power cord needs to be replaced, replace it only with another Codonics power cord manufactured specifically for your power configuration. If the device is smoking or making unusual sounds, power off and unplug the device immediately. Do not insert foreign objects of any kind into the device; doing so can constitute a safety hazard and cause extensive damage.
  • Page 13: Media Precautions

    Codonics Virtua Medical Image Viewer The Codonics Virtua Medical Image Viewer is not intended for diagnostic use. The viewer is provided for reference use only as a post-diagnostic tool. Image quality can vary greatly from system to system based on the age, quality, and resolution of the display...
  • Page 14: Medical And Patient Information

    Hazardous Material Information. European Disposal Requirements Codonics imagers and electronic accessory devices are not to be discarded or recycled; rather they are to be returned to the manufacturer. Contact Codonics directly or by the link provided for the latest information...
  • Page 15: Additional Warnings

    These discs should be destroyed to protect the confidentiality of patient data. WARNING Virtua log files might contain patient information. Use caution when distributing log files. WARNING Always power off the device and disconnect the device’s power cords before cleaning. Resume operation only after the surfaces are completely dry.
  • Page 16: De - Deutsch

    Tinte Patrone: Einer dreifarbig Patrone Nutzer Schnittstelle: Integriert / abnehmbar 15" LCD berühren Bildschirm und Fernbedienung Netz Browser Zugriff Performance: Virtua: Oben zu 30 CDs pro Stunde, 15 DVDs pro Stunde (basierend auf ein typisch klinisch Studie und Netzwerk Aufbau)
  • Page 17: Produkt Information

    Virtua XR: Oben zu 62 CDs pro Stunde, 31 DVDs pro Stunde (basierend auf ein typisch klinisch Studie und Netzwerk Aufbau) Prozessor: Intel® Celeron® G3900 Erinnerung: 4 GB Daten Lager: 120 GB Schnittstelle: 10 / 100Base-T / Gigabit Ethernet (RJ-45) Netzwerk Protokolle: DICOM Geschäft SCP (oben zu 24 gleichzeitig Verbindungen)
  • Page 18: Stromspannung Warnung

    Ort von Beachtung Etikette beim oben von Regler Ort von Beachtung Etikette beim Rückseite von Recorder Ort von ESD Etiketten beim Rückseite von Regler (Anzeige Arm nicht befestigt) Stromspannung Warnung Das Ausruf Punkte innerhalb ein gleichseitig Dreieck und Person lesen ein Handbuch Symbol sind beabsichtigt zu aufmerksam das Nutzer zu das Gegenwart von wichtig Betriebs und Instandhaltung (Wartung) Anleitung im das Literatur Begleitet Dies Gerät.
  • Page 19: Laser Warnung

    KLASSE 1 LASER PRODUKT LASER KLASSE 1 Beachtung Das Beachtung Etikette zum das Virtua-2 Modell, welche ist angebracht zu das oben von das Regler ist gezeigt unten. Das Leistung Verbrauch von das Regler und Recorder ist angegeben durch das Leistung Schalter von...
  • Page 20: Seriennummer Nummer, Aufbau, Datum Code, Und Änderung Codes

    Seriennummer Nummer Etikette ESD Vorsicht Verbindungen zu andere Stücke von Ausrüstung sind gemacht beim das Rückseite von das Codonics Virtua Medical Disc Verlag. Diese Anschlüsse sind mit einem vorsorglichen ESD-Warnsymbol gekennzeichnet, wie unten gezeigt. Berühren Sie keinen der Stifte dieser Anschlüsse. Wenn Sie Verbindungen zum Gerät herstellen, geschieht dies am besten, wenn das Gerät angeschlossen, aber nicht eingeschaltet ist.
  • Page 21: Potenzial Zum Radio Frequenz Interferenz Auf Gerät Operation

    Kommunikation Ausrüstung aus von das sofortig Bereich. Potenzial zum Radio und Fernsehen Interferenz Das Codonics Virtua Medical Disc Publisher erzeugt und verwendet Hochfrequenzenergie. Wenn diese nicht ordnungsgemäß installiert und verwendet wird, kann dies in strikter Übereinstimmung mit den Anweisungen des Herstellers zu Störungen des Radio- und Fernsehempfangs führen.
  • Page 22 WARNUNG tragbar RF Kommunikation Ausrüstung (einschließlich Peripheriegeräte eine solche wie Antenne Kabel und extern Antennen) sollte Sein benutzt Nein näher als 30 cm (12 Zoll) zu irgendein Teil von das Virtua, es ist Kabel, oder Zubehör. Andernfalls, Degradierung von das Performance von Dies Ausrüstung könnten Ergebnis.
  • Page 23: Sicherheit Vorsichtsmaßnahmen

    Sicherheit Vorsichtsmaßnahmen noch nie verbinden Dies Gerät zu irgendein Auslauf oder Leistung liefern Das hat ein Stromspannung oder Frequenz anders als Das angegeben und einstellen auf das Rückseite von das Gerät. Wann Wartung das Gerät, immer Leistung es aus mit das Grün Sanft Leistung Taste auf das Regler Vorderseite Panel, Wende das hart Leistung Schalter beim das Rückseite von das Regler und Recorder zu das 0 (aus) Position, dann Ziehen Sie den Stecker heraus das Gerät.
  • Page 24: Ort Vorsichtsmaßnahmen

    Wenn das Leistung Kabel Bedürfnisse zu Sein ersetzt, ersetzen es nur mit Ein weiterer Codonics Leistung Kabel hergestellt speziell zum Ihre Leistung Aufbau. Wenn das Gerät ist Rauchen oder Herstellung ungewöhnlich Geräusche, Leistung aus und Ziehen Sie den Stecker heraus das Gerät sofort.
  • Page 25: Reinigung Vorsichtsmaßnahmen

    Information. Nur benutzen Codonics-empfohlen Scheiben zu dafür sorgen Kompatibilität mit das Aufzeichnung und Beschriftung System von das Gerät. Kontakt Codonics Kunde Bedienung zum ein Strom Liste von empfohlen Scheiben und Lieferanten. Nur benutzen Codonics-empfohlen Tinte Patronen zu dafür sorgen richtig Operation von das Gerät und richtig Beschriftung von das Rabatt.
  • Page 26: Codonics Virtua Medizinisch Bild Zuschauer

    Hitze wie Dies kann stören mit Daten Abruf und Etikette Lesbarkeit. Codonics Virtua Medizinisch Bild Zuschauer Das Codonics Virtua Medizinisch Bild Zuschauer ist nicht beabsichtigt zum Diagnose benutzen. Das Zuschauer ist unter der Voraussetzung zum Referenz benutzen nur wie ein nach der Diagnose Werkzeug.
  • Page 27: Indikationen Zum Benutzen

    DE 50419 Symbol Indikationen zum Benutzen Virtua Serie Geräte sind beabsichtigt zum Digital medizinisch Bild Kommunikation, wird bearbeitet, und Lager. Funktionen einschließen Transfer, “Betrachten Klient auf CD / DVD ” Bereitstellung, Lager, Archiv, Aufzeichnung, und Beschriftung von CD / DVD Medien. Wann konfiguriert, das Fähigkeit zu umleiten alle oder Teil von ein Röntgen Studie zu Codonics Horizont Serie Medizinisch Hardcopy Trocken Imager (Vormarkt Benachrichtigung...
  • Page 28 Wort "Ablehnen" oder nicht beschriftet beim alle. Diese Scheiben sollte Sein zerstört zu schützen das Vertraulichkeit von geduldig Daten. WARNUNG Virtua Log Dateien könnte enthalten geduldig Information. Benutzen Vorsicht wann verteilen Log Dateien. WARNUNG Immer Leistung aus das Gerät und trennen das Geräte Leistung Schnüre Vor Reinigung.

This manual is also suitable for:

Virtua xr