FAM3200 ARMORED VARIABLE AREA PURGEMETER | CI/FAM3200-EN REV. D

Disposal

Note
Products that are marked with the adjacent symbol
may not be disposed of as unsorted municipal waste
(domestic waste).
They should be disposed of through separate
collection of electric and electronic devices.
This product and its packaging are manufactured from materials
that can be recycled by specialist recycling companies.
Bear the following points in mind when disposing of them:
As of 8/15/2018, this product will be under the open
scope of the WEEE Directive 2012/19/EU and relevant
national laws (for example, ElektroG - Electrical
Equipment Act - in Germany).
The product must be supplied to a specialist recycling
company. Do not use municipal waste collection points.
These may be used for privately used products only in
accordance with WEEE Directive 2012/19/EU.
If there is no possibility to dispose of the old equipment
properly, our Service can take care of its pick-up and
disposal for a fee.

10 Specification

Material load

Figure 7: PS: pressure, TS: temperature
Maximum permissible operating pressure
The permissible operating pressure is dependent on the optional
device equipment.
Model
Option
FAM3225 /
Without
FAM3255
FAM3220 /
With needle valve
FAM3250
With differential pressure
regulator
Permissible measuring medium temperature
Permissible measuring medium temperature depending on
gasket material.
Gasket materials
O-ring / meter tube holder
Viton A® / PVDF
Buna N® / PVDF
Kalrez® / PTFE
Viton A / PTFE
Buna N / PTFE
EPDM / PVDF
Viton / none
Buna N / none
Kalrez / none
Note
The permissible measuring medium temperature range is
dependent on which gasket material is used.
The details on the factory and name plate of the flowmeter must
be strictly observed.
Failure to comply with this information can result in destruction
of the gasket and the flowmeter.
13
Max. permissible operating
pressure
100 bar (1450.38 psi)
40 bar (580.15 psi)
14 bar (203.05 psi)
(Standard, higher pressures
available on request)
T
min / max
medium
−20 to 100 °C (−4 to 212 °F)
−30 to 100 °C (−22 to 212 °F)
0 to 180 °C (32 to 356 °F)
−20 to 180 °C (−4 to 356 °F)
−20 to 100 °C (−4 to 212 °F)
−50 to 100 °C (−58 to 212 °F)
−20 to 180 °C (−4 to 356 °F)
−30 to 100 °C (−22 to 212 °F)
0 to 180 °C (32 to 356 °F)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fam3220Fam3250Fam3225Fam3255