Troubleshooting Guide - SwitchDoc Labs WeatherRack2 Installation Manual

Table of Contents

Advertisement

Figure 52
Replace the FT-020T Sensor Array and F016TH thermo-hygrometer transmitter batteries once every 1-2 years

Troubleshooting Guide.

Problem: F016TH Temperature sensor reads too high in the daytime.
Solution: Make sure the F016TH thermo-hygrometer is mounted in a shaded area if outdoors . The preferred
location is a north facing wall because it is in the shade most of the day.
Problem: Indoor and Outdoor Temperature do not agree
Solution: Allow up to one hour for the sensors to stabilize due to signal filtering. The indoor and outdoor
temperature sensors should agree within 2 °C (the sensor accuracy is ± 1 °C).
Match the indoor and outdoor temperature to a known source.
Problem: Indoor and Outdoor Humidity do not agree
Solution: Allow up to one hour for the sensors to stabilize due to signal filtering. The indoor and outdoor
humidity sensors should agree within 10 % (the sensor accuracy is ± 5 %).