6.4 MODULE 4 - S
The Setpoint Output Parameters are only active when an optional Setpoint
Output Module is installed in the meter. Some parameters in the menu will not
appear depending on the Setpoint Assignment and Setpoint Output Action. The
Setpoint Parameter Availability chart below illustrates this.
SETPOINT SELECT
SPt SEL
NO
NO
Select the Setpoint Output to be programmed, starting with Setpoint 1. The
n
"
" in the following parameters reflects the chosen Setpoint number. After
Setpoint 1 is completely programmed, the display returns to
steps for Setpoint 2 if both Setpoints are used in the application.
NO
Select
to exit the Setpoint programming module. The number of Setpoints
available is dependent on the Setpoint option module installed.
SETPOINT 2 ENABLE (SP2 Only)
SP2 Enb
NO
NO
Select
to enable Setpoint 2 and access the setup parameters. If
YES
SPt SEL
selected, the unit returns to
SETPOINT ASSIGNMENT
SPn ASN
Count A
Count A
Select the display to which the Setpoint is assigned.
PARAMETER
SPn tOUt
SPn VAL
SPn OUt
SPn LIt
SPn P-UP
SPn tYPE
SPn StbY
SPn AUtO
SP1 OFF2
SP2 OFF1
SPn rSt
SPn ChC
* BOUNDARY Setpoint Action not applicable for Counter B Assignment
ETPOINT
PARAMETER MENU
SP1
SP2
SPt SEL
. Repeat
YES
and Setpoint 2 is disabled.
Count b
rAtE
SETPOINT PARAMETER AVAILABILITY
DESCRIPTION
Setpoint Output Time-out Value
Setpoint Value
Setpoint Output Logic
Setpoint Annunciator
Setpoint Output Power-up State
Setpoint Boundary Type
Standby Operation (Low acting only)
Counter Auto Reset
SP1 Output Off at SP2 (SP1 only)
SP2 Output Off at SP1 (SP2 only)
Output Reset with Manual Reset
Change Display Color w/ Output State
O
P
UTPUT
ARAMETERS
SETPOINT OUTPUT ACTION
SPn ACt
LAtCH
The parameter selects the action of the Setpoint Output as described in the
chart. Boundary output action is not applicable for Counter B assignment.
SPT ACTION DESCRIPTION
Latched Output Mode
LAtCH
t-OUt
Timed Output Mode
Boundary Mode
(High Acting Type)
bOUNd
Boundary Mode
(Low Acting Type)
NO
is
COUNTER ASSIGNMENT (A or B) *
TIMED OUT
BOUNDARY
LATCH
t-OUt
bOUNd
LAtCH
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
No
No
Yes
No
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
Yes
Yes
11
(
)
4-SEtPt
LAtCH
t-OUt
OUTPUT ACTIVATES
OUTPUT DEACTIVATES
When Count =
At Manual Reset
Setpoint
(if
When Count =
Setpoint
Output Time-Out
When Count
Setpoint
When Count
Setpoint
RATE ASSIGNMENT
TIMED OUT
BOUNDARY
LATCH
t-OUt
bOUNd
LAtCH
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
Yes
No
Yes
Yes
Yes
Yes
bOUNd
SPn rSt
=
YES
)
After Setpoint
When Count
< Setpoint
When Count
>
Setpoint