INSTALLATION
• Avoid reflective background or objects in the detection field of the sensor.
• Avoid high intensity lighting in the detection field.
• Do not cover the sensor.
• Do not touch the optical parts.
1
Using the mounting template, cut
an opening in the desired location
for the sensor.
4
Once inserted, secure the 2
mounting screws.
6
Remove the face by inserting a
screwdriver as shown.
If the LED continues to flash, the sensor
must be adjusted (see next page).
Page 2 of 4
2
Loosen the mounting screws and
manually adjust the sensor angle.
Be sure tighten the screws when
finished.
5
NO POWER
DETECTION
NO DETECTION
Wire the sensor according to the diagram.
7
Press the push button to launch
an automatic setup. The LED will
flash red/green.
The sensor can also be installed on the surface by using the
surface mount accessory (sold separately).
3
Connect the cables and insert the
sensor in the opening from step 1.
}
BLACK
POWER SUPPLY
RED
(12 – 24 VAC/VDC)
}
WHITE
COM
GREEN
N.O.
YELLOW
N.C.
}
PURPLE/YELLOW
MONITORING
PURPLE
N.O.
N.C.
WHITE/YELLOW
WHITE/GREEN
8
When the LED is no longer flashing,
the sensor is set up. Now secure the
face and test for proper operation.
75.5390.02 SMART FOCUS 20191002