The following diagram shows the entire electrical
installation for the equipment.
3x400V+N+PE
L1
L1
L2
L2
L3
L3
N
N
1
3
5
K1
2
4
6
97
Q1
98
PE
X1
U
V
W
M
M1
~
3
PE
POMPE
PUMP
In the control box, connect the pump cable and the level
float switches. See details of connection.
STOP
RESET
95
NC 96
97
N0
2 T1
4 T2
6 T3
M
3
POMPE
PUMP
8
L1
S.NIVEAU
S.ALARME
S.LEVEL
S.ALARM
AUTO
MANUAL
95
96
95
Q1
96
P.THERMIQUE
P.THERMIC
A2
K1
A1
230VAC
230VAC
N
MARCHE POMPE
ALARME
PUMP RUN
ALARM
N
98
A2
A1
14/22
N0/NC
Fix the cabinet to the wall using 4 screws.
L1
97
Q1
98
P.THERMIQUE
P.THERMIC
N
Installation inside the tank
(Installation for wall cabinet and top cabinet)
CAPTEURS
SENSORS