Electrical Installation - Beko METPOINT UD01 Installation And Operating Manual

Plug-on display for transducer
Table of Contents

Advertisement

Installation and operating manual

4. Electrical installation

For the electrical installation, refer to the table and wiring diagrams below.
16
Electrical connections
Diagram
Pin assignment
1 – power supply (+) 24V DC
2 – not assigned
3 – power supply (-) 0V or GND
4 – not assigned
5 – ground
1 – power supply (+) 24V DC
Wire colour: BROWN
3 – power supply (-) 0V or GND
Wire colour: BLUE
EN
METPOINT
UD01
®

Advertisement

Table of Contents
loading

Table of Contents