7. Within the Channel Code section, enter a valid Channel number to emulate Channel messages (i.e.,
Push/Release, CHON, and CHOFF) for the specified <D:P:S>.
8. Select the On or Off buttons to Emulate Channel ON (CHON) and Channel OFF (CHOFF)
messages for the specified <D:P:S>.
9. Select the Push button to Emulate a push/release on the channel specified. You can click and hold
down the Push button to see how the device/Master responds to the push message.
10. Within the Level Code section, enter a valid Level number and Level data value for the specified
<D:P:S> and press the Send button to transmit this data.
Valid Level Data Types and Ranges
CHAR
INTEGER
SINTEGER
LONG
SLONG
FLOAT
11. Within the Command and String fields, you can enter any number of messages that can be sent as
either a String or Command.
12. To Emulate sending a String or Command, type a String or Command within the corresponding
field and press the Send button to transmit this data.
NI-3101-SIG Signature Series NetLinx Integrated Controller
The Device, Port, and System value ranges are 1 - 65535.
The Channel number range is 1 - 65535.
The Level number range is 1 - 65535.
The list below contains the valid Level data types and their ranges:
Minimum Value
-3.402823466e+38
When entering a send command (in the context of this dialog) do not include the "send c" or
"send_command" in the statement - only type what would normally occur within the quotes,
but don't include the quotes either. For example to send the "CALIBRATE" send command,
simply type CALIBRATE (no quotes) rather than SEND_COMMAND <dev>
"CALIBRATE".
String Expressions start and end with double quotes (" "). Double quotes are not escaped;
instead, they are embedded within single quotes. String expressions may contain string
literals, decimal numbers, ASCII characters and hexadecimal numbers
(prepended with a $), and are comma-delimited.
String Literals start and end with single quotes ( ' ). To escape a single quote, use ''' (three
single quotes).
NetLinx Security within the Web Server
0
0
-32768
0
-2147483648
Maximum Value
255
65535
32767
429497295
2147483647
3.402823466e+38
69