AMX NetLinx NI-3101-SIG Operation/Reference Manual page 105

Signature series netlinx integrated controller
Hide thumbs Also See for NetLinx NI-3101-SIG:
Table of Contents

Advertisement

Manage Other Devices Page (Cont.)
Feature
Configure Binding Options (Cont.):
Enable Subnet Match
Purge Bound Modules on Reset
Save Settings
Enable/Disable Module Search via Internet • Clicking this button toggles the capability of searching the
Device Configuration Pages:
Manage Device Modules:
Select File to Delete
NI-3101-SIG Signature Series NetLinx Integrated Controller
NetLinx Security within the Web Server
Description
This selection allows an end-user to toggle whether or not
IP devices should only be detected/discovered if they are on the
same IP Subnet as the Master.
• This selection indicates that all modules should be deleted from
the /bound directory upon the next reboot.
• During the binding process, the associated Duet modules for a
device are copied from the /unbound directory into a protected
/bound area.
• Due to the dynamic nature of Java class loading, it is not safe to
delete a running .JAR file. Therefore, this selection provides
the administrator the capability of removing existing modules
upon reboot by forcing a re-acquisition of the module at bind
time.
• This selection is a one-time occurrence. Upon the next
reboot, the selection is cleared.
Clicking this button causes the current selected checkbox values
to be saved into the system.
Internet (either AMX's site or a device specified site) for a
device's compatible Duet modules. This capability is
automatically disabled if the Master does not have Internet
connectivity.
• Upon enabling Internet connectivity, the AMX License
Agreement is displayed for acceptance (FIG. 64). The AMX
License Agreement must be accepted (by pressing the Accept
button on the upper-right of the page) for the Internet Module
search to be enabled.
• When the Internet search for modules feature is enabled (the
button then reads Disable Module Search via Internet), the
Master queries either AMX's Online database of device
Modules and/or pulls Modules from a separate site specified by
the manufacturer's device.
• This feature may be disabled later by toggling the button.
This section is optional and is only present when either
configuration links have been previously registered by a running
Duet Module, or if a discovered device supplies configuration link
information.
• If present, this section displays each link along with a
mouse-over tool-tip.
• For Duet Modules this tool-tip describes the module
configuration link.
• For discovered devices this tool-tip indicates the physical
device the configuration link is associated with.
This section displays a list of all currently loaded Duet Modules/
.JAR files on the Master (resident within the /unbound directory);
as well as providing those interfaces necessary to delete, add,
and retrieve these modules.
• This field provides the listing of loaded Modules/.JAR files.
• These entries can be selected for deletion or archiving.