NOTE : The quick connector parts must be placed outside of room. Using wall hole sleeve, cap and neoprene
to seal the wall hole.
7.
In order to prevent the quick connector parts from being exposed in the air, the sound deadening
pads are supposed to be used during the installation.
8.
Wrap up the quick connectors with the sound deadening pads, pack down the pads solid as tightly.
9.
Then wrap up the connectors with the black insulation material, for the top exposed part, use the
white insulation material (supplied in Accessories box) to wrap it up completely.
10.
At last, use the tape to wrap the refrigerant pipe and connecting cable together.
NOTE ON PIPING ANGLE
Refrigerant piping can exit the indoor unit from Left-rear side
(when you're facing the back of the unit)
CAUTION
Be extremely careful not to dent or damage the piping while bending them away from the unit. Any dents
in the piping will affect the unit's performance.