Kinco FV20 User Manual
Hide thumbs Also See for FV20:

Advertisement

Chapter 1 Safety ................................................................................................................................................... 40
Chapter 2 Product Introduction ............................................................................................................................. 41
2.1 Nameplate Information ............................................................................................................................... 41
2.2 VFD Model Rule ......................................................................................................................................... 41
2.3 External dimension and weight .................................................................................................................. 42
2.3.1 External dimension and weight ....................................................................................................... 42
2.3.2 Operation panel and installation box size ....................................................................................... 44
Chapter 3 Wiring Guide Of Vfd ............................................................................................................................ 45
3.1 Wiring and Configuration of Main circuit terminal ...................................................................................... 45
3.1.2 Wiring of VFD for Basic Operation .................................................................................................. 46
3.2 Wiring and configuration of control circuit .................................................................................................. 46
Chapter 4 Operation Instructions Of Kinco Vfd .................................................................................................... 49
4.1 Using Operation Panel ............................................................................................................................... 49
4.1.2 Display status of operation panel .................................................................................................... 51
4.1.3 Panel Operation............................................................................................................................... 51
Chapter 5 Troubleshooting ................................................................................................................................... 52
Chapter 6 List Of Parameters ................................................................................................................................ 53

Directory

............................................................................. 45
39
.......................................................... 49

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FV20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kinco FV20

  • Page 1 ................45 3.1.2 Wiring of VFD for Basic Operation ....................46 3.2 Wiring and configuration of control circuit ....................46 Chapter 4 Operation Instructions of Kinco VFD ....................49 4.1 Using Operation Panel ..........................49 ............49 4.1.2 Display status of operation panel ....................51 4.1.3 Panel Operation..........................
  • Page 2 Chapter 1 Safety Chapter 1 Safety Danger Attention Only qualified personnel shall wire the drive, or it nstall the drive in places where water pipes may cause electric shock. may leak onto it. Perform the maintenance job after confirming that Don't allow screws, washers and other metal foreign the charging LED is off or the DC Bus voltage is matters to fall inside the drive, otherwise there is a...
  • Page 3 Power Model name Input Voltage/Current/freque Output Voltage/Current/freque CE certification Serial Number 2.2 VFD Model Rule FV20 4T 0075G/0110L A 037 VFD Code Software custom code FV FV Series The second generation Hardware custom code 0 Standard model 0075G 7.5KW constant torque...
  • Page 4 Chapter 2 Product introduction 2.3 External dimension and weight 2.3.1 External dimension and weight Fig 2-1FV20-4T-0185G/0220L and lower power VFD Fig 2-2FV20-4T-0220G/0300L FV20-4T-8000G Fig 2-5 FV20-4T-1000G...
  • Page 5 Chapter 2 Product introduction Table 2-1 Mechanical parameters VFD model External dimension and (mm) Weight (G.Constant torque load; Installation (kg) L.Draught fan and water hole(d) pump load) FV20-4T-0007G/0015L FV20-4T-0015G/0022L 74.5 FV20-4T-0022G/0037L FV20-4T-0037G/0055L FV20-4T-0055G/0075L FV20-4T-0075G/0110L FV20-4T-0110G/0150L FV20-4T-0150G/0185L FV20-4T-0185G/0220L FV20-4T-0220G/0300L FV20-4T-0300G/0370L FV20-4T-0370G/0450L 88.5...
  • Page 6 Chapter 2 Product introduction 2.3.2 Operation panel and installation box size Fig 2-3 Installation box dimension Note When the operation panel is mounted, the opening size of the tray is 65*130mm.
  • Page 7 Chapter 3 Wiring Guide of VFD Chapter 3 Wiring Guide of VFD 3.1 Wiring and Configuration of Main circuit terminal Table 3-1 Description of main loop terminal Terminal name Function description Single phase 220VAC input terminal R S T 3-phase 380V AC input terminal DC bus positive and negative terminal Braking resistor terminal U V W...
  • Page 8 Chapter 3 Wiring Guide of VFD 3.1.2 Wiring of VFD for Basic Operation J601 J602 J603 J604 AO1 AO2 Fig.3-1 Basic wiring chart 3.2 Wiring and configuration of control circuit 3.2.1 Wiring of control circuit terminal. Wire the terminals correctly before using the Drive. Refer to the table 3-2 for control circuit terminal function Table 3-2 Control circuit terminal function Sequence No.
  • Page 9 Chapter 3 Wiring Guide of VFD Refer to table 3-3 for description of each terminal Table 3-3 function list of each list Category Terminals Name Function description Specification PE terminal connected to shielding layer. 485 communication cable, Analog signal cable, Connected to PE terminal of main Shield Shielded PE...
  • Page 10 Chapter 3 Wiring Guide of VFD Category Terminals Name Function description Specification Open collector When defined as Open collector output Multi- output terminal terminal,refer to the A6.14 for detail,When Optocoupler isolation output function (High-speed defined as High-speed pulse output Maximum working voltage.30v output pulse) output terminal,refer to A6.27 for detail.Maximum...
  • Page 11 Chapter 4 Operation Instructions of Kinco VFD Chapter 4 Operation Instructions of Kinco VFD 4.1 Using Operation Panel 4.1.1 Operation panel is used to setup the drive and display parameters, it is LED display. As shown in Fig.4-1 Current limit indicator...
  • Page 12 Chapter 4 Operation Instructions of Kinco VFD FWD/REV: Light is on, VFD runs forward; Light is off, VFD runs reversely. NORM/LMT Light is on, VFD is in current limit state; Light is off, VFD is not in current limit state and can run normally.
  • Page 13 Refer to function code list in chapter 9 for 4.1.2 Display status of operation panel detail function code description. FV20 operation panel can display the parameters in stopping, operating, editing and function code.. Example 1.Set parameters 1. Parameters displayed in stopping status Example.Change the value in A0.03 from 50.00Hz to...
  • Page 14 Chapter 5 Troubleshooting Chapter 5 Troubleshooting Table 5-1 lists the possible faults of FV20, error code E001 E099. When VFD reports error, users could check this list and record the detailed fault phenomena before seeking service from supplier. Table 5-1 Faults...
  • Page 15 Chapter 6 List of Parameters Chapter 6 List of Parameters FV20 identified by The parameter descriptions are listed in the tables below. Table 6-1 Descriptions of Function Code Parameter Structure Table Name Description Function code The number of function code...
  • Page 16 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range LED Ten s place: Motor 1 type 0: asynchronous motor 1: synchronous motor LED Hundred s place: Motor 2 control mode 0: Vector control without PG 1: Vector control with PG 2: V/F control without PG 3: V/F control with PG...
  • Page 17 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range Group A1.Start and stop parameters A1.00 Starting mode 0: Start from the starting frequency 1: Brake first and then start 2: Start on the fly(including direction judgement), start at starting frequency 3: Current search type speed tracking starting (only valid in V/F control)
  • Page 18 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range A1.19 Selection of power outage 0: Current finding mode restarting mode (Only valid in V/F control; Otherwise set to 0, starting with vector tracking) 1: Vector tracking mode 2: Depend on the parameter A1.00 Group A2.Frequency setting A2.00...
  • Page 19 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range 0: Curve 1 1: Curve 2 2: Curve 3 3: Curve 4 .Keyboard potentiometer curve selection 0: Curve 1 1: Curve 2 2: Curve 3 3: Curve 4 curve selection 0: Curve 1...
  • Page 20 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range A3.15 Reference of inflection A3.17 A3.13 0.01% 100.00% 0 11000 point 2 of curve 4 A3.16 Actual value The same as A3.02 0.01% 100.00% 0 10000 corresponding to the Min reference of inflection point 2 of curve 4...
  • Page 21 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range A4.07 S curve acceleration 10.0% 50.0%(Acc time) 0.1% 20.0% 100 500 starting time A4.08 S curve acceleration 10.0% 80.0%(Acc time) 0.1% 20.0% 100 800 ending time A4.09 S curve deceleration 10.0% 50.0%(Dec time)
  • Page 22 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range A5.16 Reference torque filtering 0 65535ms 0 65535 time A5.17 Excitation current 0.00 200.0 0.01% 1000 0 20000 proportional gain A5.18 Excitation current integral 0.000 20.000s 0.001s 0 20000 gain...
  • Page 23 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range 28: Preset frequency 2 29: Preset frequency 3 30: Preset frequency 4 31: Acc/Dec time 1 32: Acc/Dec time 2 33: Multiple close-loop reference selection 1 34: Multiple close-loop reference selection 2 35: Multiple close-loop reference...
  • Page 24 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range A6.07 Reserved 0 65535 A6.08 Terminal filter 0 500ms 0 500 A6.09 Terminal control mode 0: 2-wire operating mode 1 selection 1: 2-wire operating mode 2 2: 3-wire operating mode 1 3: 3-wire operation mode 2 4: 2-wires operation mode 3...
  • Page 25 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range 13: PLC running cycle complete signal 14: Limit of swing frequency upper/lower limit 15: Drive ready (RDY) 16: Drive fault 17: Switching signal of host 18: Reserved 19: Torque limiting 20: Drive running forward/reverse...
  • Page 26 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range BIT0 BIT3.X1 X4 BIT0 BIT1.X5 X6 A6.27 Y1 terminal output 0 50: D0 is used as Y terminal output. 0 88 51 88: D0 function 0: Running signal(RUN) 1: frequency arriving signal(FAR) 2: frequency detection threshold...
  • Page 27 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range 63: Keyboard potentiometer 64: DI 65: Percentage of host(0 4095) 66 88: Reserved A6.28 Max. output pulse 0.1 100.0(Max.100.0k) 0.1kHz 10.0 1 1000 frequency A6.29 Center point of pulse 0: No center point output selection...
  • Page 28 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range A6.40 AI1 gain 0.00% 200% 0.01% 100% 1 20000 A6.41 AI2 gain 0.00% 200% 0.01% 100% 1 20000 A6.42 Keyboard potentiometer 0.00% 200% 0.01% 100% 1 20000 gain A6.43...
  • Page 29 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range 1: Enable Thou : Reserved A8.01 Fault masking : Communication 2000 0 2222H selection 1 fault masking selection : Relay fault masking selection : EEPROM fault masking selection place of LED: Reserved 0: Disable.Stop when fault happen...
  • Page 30 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range b0.02 Asynchronous motor 1 0.1 999.9A 0.1A Determined 1 9999 rated current by model b0.03 Asynchronous motor 1 1.00 1000.00Hz 0.01Hz Determined rated frequency by model 30000 b0.04 Asynchronous motor 1...
  • Page 31 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range b0.19 Synchronous motor 1pole 1 40 1 40 number b0.20 Synchronous motor 1 0 60000RPM 1RPM 1500RPM 0 60000 rated speed b0.21 Synchronous motor 1 0.00% 50.00% 0.01% Determined...
  • Page 32 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range b1.08 AVR function 0: Disable 1: Enable all the time 2: Disabled in Dec process b1.09 VF Output Voltage 0: None Selection 1: AI1 2: AI2 3: Keyboard potentiometer b1.10 VF Output Voltage...
  • Page 33 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range b2.12 Frequency decrease rate 0.00 99.99Hz/s 0.01 10.00 0 9999 at voltage compensation Hz/s Hz/s b2.13 Zero-frequency 0.00 300.00Hz 0.01Hz 0.50Hz 0 30000 Operation threshold b2.14 Zero-frequency 0.00 300.00Hz...
  • Page 34 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range b3.18 Input parameter mapping Input parameter mapping 1 12 0 1000 1 12 b3.29 Group b4.Keyboard parameters b4.00 Key-lock function 0: The keys on the operation panel are selection not locked, and all the keys are usable.
  • Page 35 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range BIT1: Setting frequency(Flick, Not display in energy feedback mode) BIT2: Output current (Not display when VFD stop, Display grid current input in energy feedback mode) BIT3: Output voltage (Not display when VFD stop, Display grid voltage input in energy feedback mode)
  • Page 36 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range 3: User menu (reserved) 4: proofreading menu b4.12 Reserved 0 65535 b4.15 b4.16 Standard / High frequency 0: Standard frequency switching 1: High frequency b4.17 Fast current limit enable 0: closed 1: enable...
  • Page 37 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range b5.14 Asynchronous motor 2 0 255 0 255 oscillation inhibition coefficient b5.15 Synchronous motor 2 0.4 999.9KW 0.1KW Determined 4 9999 rated power by model b5.16 Synchronous motor 2 0 inverter rated voltage (F82.04)
  • Page 38 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range b5.30 Motor 2 PG type 0: ABZ incremental type 1: UVW incremental type 2: Rotary encoder type 3: sin/cos type b5.31 Motor 2 Number of pulses 1 10000 2048 1 10000...
  • Page 39 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range 5: MAX(AI1 AI2) 6: DI C1.03 Digital setting ofreference -10.00V 10.00V 0.01 0.00 0 2000 C1.04 Close-loop speed 0 39000RPM 1RPM 0 39000 reference C1.05 Min reference 0.0% (C1.07)(Ratio of Min reference 0.1%...
  • Page 40 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range C1.24 Preset close-loop -10.00V 10.00V 0.01V 0.00V 0 2000 reference 6 C1.25 Preset close-loop -10.00V 10.00V 0.01V 0.00V 0 2000 reference 7 C1.26 Preset close-loop -10.00V 10.00V 0.01V...
  • Page 41 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range 0: Disable 1: Save the segment frequency when power off : Time unit selector for each step 0: Second 1: Minute C2.01 Step 1 setting 0 323H 0: Multiple frequency N (Ncorresponding to current step)
  • Page 42 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range C2.24 Step 12 operating time 0.0 6500.0 20.0 0 65000 C2.25 Step 13 setting Same as C2.01 0 323H C2.26 Step 13 operating time 0.0 6500.0 20.0 0 65000 C2.27...
  • Page 43 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range d0.09 Motor power 0.0 200.0%(Corresponding to the 0.1% 0.0% 0 2000 d0.10 -300.00 300.00Hz 0.01 0.00 0 60000 Motor estimated frequency d0.11 Motor actual frequency -300.00 300.00Hz 0.01 0.00...
  • Page 44 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range d0.30 Total conduction time 0 65535 hours 1 hours 0 65535 d0.31 Total operating time 0 65535 hours 1 hours 0 65535 d0.32 0 65535 hours 1 hours 0 65535 d0.33...
  • Page 45 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range 16: EEPROM R/W fault (E016) 17: VFD cannot get communication with host. 18: Power board/drive board/contactor damage causes contactor abnormal. 19: Hall/drive board abnormal causes current detective circuit fault.
  • Page 46 Chapter 6 List of Parameters Function Factory Setting Name Descriptions Unit Modif. code setting range d1.01 Bus voltage of the latest 0 999V 0 999 failure d1.02 Actual current of the latest 0.0 999.9A 0.1A 0.0A 0 9999 failure d1.03 Operation frequency of 0.00Hz 300.00Hz 0.01Hz...
  • Page 48 K2M19-1809...