7. For signals to reach the C190 connector, complete step a through step d. If it is a Raven controlled machine, it
may already be connected.
a.
Connect the Hawkeye
and C190. These connections may already be made on a Raven controlled machine.
b. Remove the cap from the C10R (RAVEN SIGNAL NODE).
c.
Connect the C10 (CNTRL SIGNAL) to C10R (RAVEN NODE SIGNAL).
d. Place the cap on C10E (EXT SIGNAL).
8. Remove the plug from one of the two highlighted locations on the CAN PCB in the electrical box.
9. Locate the connector labeled RVN CAN to RVN Node on the CAN PCB and move it to one of the open slots
made by removing the plug earlier.
FIGURE 4. Hawkeye Node Connected to ISOBUS
10. Use a 1-1/2" hole saw to drill a hole through the back of the electrical box in a location where the Hawkeye
system will not interfere with the existing electrical components (refer to Figure 5 on page 32).
NOTE:
Be careful not to damage any existing electrical components while drilling. This hole will be used later
to connect the chassis cable to the electrical box cabling for final system connections.