C
4
HAPTER
VALVE MOUNTING INTERFERENCE AND OBSTRUCTIONS
In some locations on the spray boom, boom equipment or hardware may interfere with mounting the Hawkeye
nozzle control valves. In these locations, there are a few options to get around the interferences:
1. Rotate the nozzle control valve so the round, low profile side of the NCV is towards the interference.
FIGURE 10. Modified Nozzle Control Valve Installation
2. Loosen the brackets and slide them out of the way of the NCV. Verify the brackets still adequately support the
components as intended. Do not remove the brackets completely.
3. If the first two options do not solve the interference, swap the AGCO nozzle body for a triple nozzle body
(provided in the kit) with the threaded connection for the Hawkeye
FIGURE 11. Triple Nozzle Body Installed
NOTE:
Avoid removing of any existing boom hardware or support brackets where applicable during
installation of the Hawkeye
24
®
nozzle control valves.
Hawkeye® Installation Manual for RoGator C-Series RG900, RG1100, RG1300
®
valve facing away from the interference.
®