Operation Test; Manual Operation Test - Macurco CD-6G Operation Manual

Carbon dioxide detector, controller and transducer
Hide thumbs Also See for CD-6G:
Table of Contents

Advertisement

Available languages

Available languages

Macurco CD-6G Operation Manual

6.3.1 Operation Test

Check that the green CD-6G status indicator LED light is illuminated continuously. If not, do not proceed with the tests. If the
unit is in error mode, contact your local representative or Macurco technical support representative for information on
resolving the problem.
1. Remove the single screw in the middle of the front cover of the CD-G.
2. Remove the front cover.
3. Observe the LED light on the front of the CD-6G.
4. If the light is solid green proceed to step 6.
5. If the green status indicator LED light is off or flashing, refer to the General section above.
6. Locate the switch labeled ENTER/TEST on the left side of the printed circuit board. Press the Test switch once.
7. The CD-6G will step through a cycle test:
a.
The display progresses through the BUZ (Buzzer Test), Art (alarm relay test), Frt (fan relay test) then 42t (4-20
mA output test). Make sure that the settings are "on" or not disabled "diS".
b. During the first 10 seconds of the test cycle, the display will show BUZ and set off the audible buzzer. The
alarm relay will be closed, so any devices connected to that relay will be tested.
c.
The Fan relay will be activated for the next 1 minute of the test, so if the fan circuits are wired in the normal
manner, the fan should run.
d. The 4-20mA output will then ramp up from 4 to 16 mA over the next 130 seconds of the test, so if the circuit is
wired in the normal manner, the control panel or building automation system should respond.
e.
At the end of the test cycle, the fan & alarm relay will be in standby mode and the 4-20 mA output will
corresponding to the gas reading of the detector. Refer to section
value.
8. When testing is completed reassemble the unit or units.

6.3.2 Manual Operation Test

This option gives the user the opportunity to manually initiate an individual test for each relay, the analog output and the sensor
response to gas.
From normal operation mode press the
E nter
Press the
button once to get into the Test Menu.
4 2 T
4 2 T
Press the
N ext
button to scroll through the Five test options and press
4 2 T
4 2 T
Note that if the relay or 4–20 mA output has been disabled, the test selection will not be displayed in the test menu.
b UZ
- Buzzer Test, 3 seconds
4 2 T
4 2 T
A rt
- Alarm Relay Test, 5 seconds
4 2 T
4 2 T
F rt
- Fan Relay Test, 60 seconds
4 2 T
4 2 T
4 2t
- 420 loop test, 130 seconds
4 2 T
4 2 T
g tS
- Gas Test, 3 minutes (no output to the panel during the gas test)
4 2 T
4 2 T
The display will flash during the test, or in the case of the gas test, the gas level will alternate with gtS. Once the test is
complete, the display will return to a steady display. To exit the test menu, press the Next button until "End" is displayed then,
press Enter to return to normal mode.
REV – 1.0
N ext
button 2 times to get to the Test Mode (tSt).
4 2 T
4 2 T
[34-2900-0510-9 ]
3 -1 4-20mA Output Diagram
3 1 T
E nter
to initiate the selected test.
4 2 T
4 2 T
for expected
3 1 T
24
|
P a g e

Advertisement

Table of Contents
loading

Table of Contents